FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MESSAGES AND CODES<br />
COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />
CPK607E SENSE ERROR - UNKNOWN DEVICE OR DEVICE NOT ECAM CAPABLE<br />
SENSE=<br />
Reason: FAST COMPAKTOR was executed with SNAPSHOT=YES, but the current installed<br />
microcode does not support the ECAM commands required for SnapShot, probably<br />
because it was not an IBM RVA or Oracle StorageTek disk subsystem. This message<br />
is just informational; it is not normally printed unless a debugging option is enabled.<br />
Action: The volume is COMPAKTed with normal READ and WRITE CCWs.<br />
CPK608E DWASET TABLE EXHAUSTED<br />
Reason: FAST COMPAKTOR was executed with SNAPSHOT=YES, but an internal table<br />
overflowed while using SnapShot on an IBM RVA or Oracle StorageTek disk.<br />
Action: Contact INNOVATION DATA PROCESSING Technical Support.<br />
CPK609E EMC COPY REQUEST ERROR - reason<br />
Reason: The “reason” value can be either “MICROCODE LEVEL NOT HIGH ENOUGH” or<br />
“CONTROLLER DOES NOT SUPPORT EMCCOPY”.<br />
FAST COMPAKTOR was executed with EMCCOPY=YES, but the microcode level of<br />
the EMC Symmetrix specified was not high enough to support the internal EMC COPY<br />
function or the controller does not support the EMCCOPY instructions.<br />
Action: Contact EMC to upgrade your Symmetrix microcode or contact INNOVATION DATA<br />
PROCESSING Technical Support.<br />
CHAPTER 100 – PAGE 100-143 –