30.01.2015 Views

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FDR</strong>315<br />

Reason:<br />

Action:<br />

MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

DDNAME=ddn, VOL=SER=vvvvvv NOT ELIGIBLE FOR function MAXIMUM RUNS EXCEEDED<br />

1.The ABR Model DSCB on this volume does not indicate that the volume is enabled for<br />

ARCHIVE or SCRATCH (Superscratch) or the ABR Model DSCB does not exist.<br />

2.If MAXIMUM RUNS EXCEEDED is printed, more than 255 Archive Backups of this volume<br />

were done today; this limit is only enforced when the backups must be cataloged in the<br />

ABR catalog (see “Tape Format and Naming Conventions” in Section 51.1).<br />

This volume is bypassed. If you intend to do Archive Backup or Superscratch on this<br />

volume, create or update the ABR Model DSCB with <strong>FDR</strong>ABRM (Section 50.40 “VTOC<br />

Maintenance Utility (<strong>FDR</strong>ABRM)”) or ISPF panel A.I.8 (Section 90.42 “Set ABR Disk<br />

Volume <strong>Processing</strong> Options”).<br />

If the operand “NOINIT” is specified, ABR allows a simulation (SIM TYPE=) of the<br />

volume to continue.<br />

CHAPTER 100 – PAGE 100-62 –