MESSAGES AND CODES<br />
MESSAGES FROM ALL PROGRAMS (<strong>FDR</strong>99N) 100.5<br />
100.5 MESSAGES FROM ALL PROGRAMS (<strong>FDR</strong>99N)<br />
<strong>FDR</strong>990 INSTALLED INNOVATION TRIAL WILL EXPIRE ON yyyy.ddd<br />
Reason: The expiration date of a trial version of <strong>FDR</strong> has been extended successfully. It now<br />
expires on date “yyyy.ddd”.<br />
Required JCL:<br />
//EXTEND EXEC PGM=<strong>FDR</strong>EXTND,PARM=xxxx<br />
//STEPLIB DD DISP=SHR,DSN=fdr.loadlib<br />
//SYSLIB DD DISP=SHR,DSN=fdr.loadlib<br />
//SYSUDUMP DD SYSOUT=*<br />
//SYSDIAG DD SYSOUT=*<br />
The PARM= is supplied by INNOVATION DATA PROCESSING.<br />
<strong>FDR</strong>997 <strong>FDR</strong> ABNORMALLY TERMINATED VOL=vvvvvv<br />
Reason: This <strong>FDR</strong> subtask has encountered an error from which it cannot continue. A user<br />
ABEND is being issued.<br />
Action: A message detailing the error is printed.<br />
<strong>FDR</strong>998<br />
Reason:<br />
Action:<br />
program status ERRORS VOL=vvvvvv [COMPAKT BYPASSED]<br />
“program” ran to completion on volume “vvvvvv” but there were error or warning messages.<br />
“status” can be “COMPLETED WITH” or “BYPASSED DUE TO”; the latter is used for a<br />
SPLIT or SNAP if the operation did not complete successfully. A user ABEND U0888 or a<br />
condition code of 8 or higher is issued at the completion of the step. If “COMPAKT<br />
BYPASSED” is printed, <strong>FDR</strong> was requested to COMPAKT the volume after a successful<br />
backup; this is “BYPASSED” since <strong>FDR</strong> detected one or more errors.<br />
Previous message(s) describe the error; see those messages for further details.<br />
<strong>FDR</strong>999 program SUCCESSFULLY COMPLETED VOL=vvvvvv<br />
Reason: “program” ran to completion on volume “vvvvvv” without errors.<br />
CHAPTER 100 – PAGE 100-124 –