30.01.2015 Views

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MESSAGES AND CODES<br />

<strong>FDR</strong>REORG MESSAGES (<strong>FDR</strong>RNN & <strong>FDR</strong>SNN) 100.7<br />

<strong>FDR</strong>R71** FORMAT 3 DSCB POINTER MISSING -- DSN=dsname<br />

Reason: The Format 1 DSCB for a partitioned data set indicated that the data set is in more than<br />

three extents that requires that a Format 3 DSCB exist to describe the additional<br />

extents. The Format 3 pointer in the Format 1 DSCB however is zero.<br />

Action:<br />

The Format 1 DSCB for the indicated data set is invalid and the data set is bypassed. If you are<br />

licensed for COMPAKTOR, you can run a CPK MAP on the volume to identify all VTOC errors.<br />

<strong>FDR</strong>R72** ERROR READING FORMAT 3 DSCB -- R15=ccc,DSN=dsname<br />

Reason: An attempt was made to read the Format 3 DSCB for the indicated partitioned data set<br />

but it failed. “ccc” is the return code from the OBTAIN SVC.<br />

Action: The Format 1 DSCB for the indicated data set is invalid or the VTOC has been<br />

damaged. The data set is bypassed. If you are licensed for COMPAKTOR, you can<br />

run a CPK MAP on the volume to identify all VTOC errors.<br />

<strong>FDR</strong>R73** FORMAT 3 DSCB NOT RETURNED BY OBTAIN -- DSN=dsname<br />

Reason: An attempt was made to read the Format 3 DSCB for the indicated partitioned data set<br />

and the data return by OBTAIN was not a valid Format 3.<br />

Action: Probable system error or VTOC damage. The data set is bypassed. If you are licensed<br />

for COMPAKTOR, you can run a CPK MAP on the volume to identify all VTOC errors.<br />

<strong>FDR</strong>R74** MISSING EXTENT DESCRIPTOR(S) -- DSN=dsname<br />

Reason: A required extent descriptor for a partitioned data set in either a Format 1 or Format 3<br />

DSCB was null.<br />

Action: Probable system error or VTOC damage. The data set is bypassed. If you are licensed<br />

for COMPAKTOR, you can run a CPK MAP on the volume to identify all VTOC errors.<br />

<strong>FDR</strong>R75**<br />

Reason:<br />

Action:<br />

EXTENTS OUT OF SEQUENCE -- DSN=dsname<br />

While validating a partitioned data set’s extent descriptor in the Format 1 or Format 3 DSCBs, an<br />

extent sequence number was encountered that was not in the proper sequence.<br />

Probable system error or VTOC damage. The data set is bypassed. If you are licensed<br />

for COMPAKTOR, you can run a CPK MAP on the volume to identify all VTOC errors.<br />

<strong>FDR</strong>R76** INVALID FLAGS IN EXTENT DESCRIPTOR -- DSN=dsname<br />

Reason: While validating a partitioned data set’s extent descriptor in the Format 1 or Format 3<br />

DSCBs, an invalid extent descriptor flag was encountered.<br />

Action: Probable system error or VTOC damage. The data set is bypassed. If you are licensed<br />

for COMPAKTOR, you can run a CPK MAP on the volume to identify all VTOC errors.<br />

<strong>FDR</strong>R77** INVALID CYLINDER/TRACK ADDRESS -- DSN=dsname<br />

Reason: While validating a partitioned data set’s extent descriptor in the Format 1 or Format 3<br />

DSCBs, a cylinder or track address was encountered that is not valid for the device.<br />

Action: Probable system error or VTOC damage. The data set is bypassed. If you are licensed<br />

for COMPAKTOR, you can run a CPK MAP on the volume to identify all VTOC errors.<br />

See message CPK512I for a possible cause of this error.<br />

<strong>FDR</strong>R78** FORMAT 1 DSCB MISSING FOR DSN=dsname<br />

Reason: The Format 1 DSCB for the indicated VSAM data component could not be found.<br />

Action: Probable system error or VTOC damage. The data set is bypassed.<br />

<strong>FDR</strong>R79** TRKCALC FAILURE -- RETURN CODE=ccc,DSN=dsname<br />

Reason: A TRKCALC macro failed. “ccc” is the return code from TRKCALC.<br />

Action: Contact INNOVATION DATA PROCESSING for assistance.<br />

CHAPTER 100 – PAGE 100-151 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!