MESSAGES AND CODES<br />
MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />
6 type UNIT NOT FOUND – The device address specified by xxxxUNIT=<br />
was not found in the current I/O configuration. Be sure you specified a 4-<br />
digit hex address; add a leading zero if required.<br />
7 type UNIT NOT DASD – The device address specified by xxxxUNIT= was<br />
defined as a type other than disk in the current I/O configuration.<br />
8 type UNIT IS NOT OFFLINE – The disk address specified by xxxxUNIT= was<br />
not varied offline to z/OS. If you are sure that you want to use this device as an<br />
<strong>FDR</strong>INSTANT target, vary it offline. Note that <strong>FDR</strong>INSTANT completely<br />
overlays that target volume and all existing data on the volume is lost.<br />
9 UNKNOWN DEVICE OR DEVICE NOT type CAPABLE – Either the source<br />
volume specified by VOL= or the target volume specified by xxxxUNIT= is<br />
capable of the special hardware feature requested (e.g, “ECAM” is the special<br />
command set used to perform SnapShot).<br />
9 UNABLE TO OBTAIN SYMMETRIX DEVICE NUMBER – <strong>FDR</strong> was unable<br />
to determine the z/OS device address of the BCV assigned to the online<br />
volume being dumped. Possibly it is not in the I/O configuration or is in a<br />
different Symmetrix. Try specifying BCVUNIT= on the MOUNT statement.<br />
9 UNABLE TO OBTAIN PPRC DUPLEX NUMBER – <strong>FDR</strong> was unable to<br />
determine the z/OS device address of the ShadowImage volume assigned<br />
to the online volume being dumped. Possibly it is not in the I/O configuration<br />
or is in a different disk subsystem.<br />
9 UNKOWN DEVICE OR DEVICE NOT FLASHCOPY CAPABLE – Device<br />
is not capable of FlashCopy or FlashCopy cannot be used between the<br />
source and target devices specified.<br />
A UNEQUAL SOURCE/TARGET CONTROLLER FRAME SERIAL NO. –<br />
The source volume specified by VOL= and the target volume specified by<br />
xxxxUNIT= are not both in the same disk subsystem (for FlashCopy V1,<br />
they must be in the same logical subsystem (LSS)).<br />
A SYMMETRIX QUERY FAILED – A query to the EMC Symmetrix to get<br />
A<br />
BCV information failed.<br />
DEVICE IS NOT IN DUPLEX STATE – No PPRC session exists for the<br />
primary device.<br />
B SNAP STATUS INDICATES FAILURE – Contact INNOVATION DATA<br />
PROCESSING for assistance.<br />
B UNKNOWN DEVICE STATE FLAG=xx – Contact INNOVATION DATA<br />
PROCESSING for assistance.<br />
C<br />
SNAP STATUS INDICATES TIME OUT – An internal time-out occurred in<br />
the hardware. If it is repeatable, contact INNOVATION DATA<br />
PROCESSING for assistance.<br />
D SNAP STATUS INDICATES INVALID EXECUTE ATTEMPTED – Contact<br />
INNOVATION DATA PROCESSING for assistance.<br />
E SNAP STATUS INDICATES COUNT FIELD INCOMPATIBILITY –<br />
F<br />
G<br />
Contact INNOVATION DATA PROCESSING for assistance.<br />
I/O ERROR DURING PROCESSING – An unexpected I/O error occurred while<br />
processing the special hardware request. The error is documented by another<br />
message. This can occur at DRP during a RESTORE procedure when the catalog<br />
being used has the backup entry pointing to the instant offline volume instead of the<br />
backup tape. This can occur when the ABR catalog being used was captured before<br />
the <strong>FDR</strong>ABR DUMP process but after the SNAP, SPLIT, PSPLIT, or FCOPY<br />
process. Contact INNOVATION DATA PROCESSING for assistance.<br />
MESSAGE ID=mmmm STATUS CODE=ssss – ECAM message number<br />
“mmmm” was issued to the SnapShot device. The message was accepted but it<br />
returned status code “ssss”. Contact INNOVATION DATA PROCESSING for<br />
assistance.<br />
CHAPTER 100 – PAGE 100-50 –