MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

<strong>FDR</strong>278 VOLUME vvvvvv INELIGIBLE FOR CONVERSION: REASON=reason<br />

Reason: The volume specified could not be converted to the desired status because it was not eligible.<br />

Action: Determine from the reason printed why the volume was not eligible. If necessary, call<br />

INNOVATION DATA PROCESSING for assistance.<br />

<strong>FDR</strong>279 ddname DD MISSSING<br />

Reason: A required DD statement was not found.<br />

Action: Supply the missing DD statement.<br />

<strong>FDR</strong>280 ddname OPEN ERROR<br />

Reason: A required data set failed to open.<br />

Action: Determine the reason for the failure and rerun the job.<br />

<strong>FDR</strong>281 JOBCAT/STEPCAT DD NOT ALLOWED<br />

Reason: A JOBCAT or STEPCAT DD statement was found in the JCL. JOBCAT and STEPCAT<br />

DD statements are not allowed with <strong>FDR</strong>CONVT.<br />

Action: Use the INCAT parameter to specify catalogs to be searched for data sets catalogued<br />

outside the standard order of search.<br />

<strong>FDR</strong>282 SMS NOT ACTIVE ON SYSTEM<br />

Reason: The SMS address space is not active. <strong>FDR</strong>CONVT requires that SMS be active in order<br />

to run. This message may also occur if the operating system is not an MVS/XA or<br />

MVS/ESA system or if the Common VTOC Access Facility (CVAF) is not available.<br />

Action: Start the SMS address space or run the job on a system where SMS is active.<br />

<strong>FDR</strong>283 NO VOLUMES TO PROCESS<br />

Reason: No volumes were online that met the specification in the VOL= parameter. <strong>FDR</strong>CONVT<br />

has nothing to do.<br />

Action: Specify the correct volumes to be processed in the VOL= parameter.<br />

<strong>FDR</strong>284 VVDS CREATED ON VOLUME=vvvvvv<br />

Reason: <strong>FDR</strong>CONVT created a VVDS on a volume being converted to SMS status.<br />

<strong>FDR</strong>286 MASTER CATALOG NAME NOT FOUND<br />

Reason: The name of the master catalog could not be determined. <strong>FDR</strong>CONVT must determine<br />

the master catalog name in order to run.<br />

Action: Correct any problems with the master catalog and rerun the job. If the problem cannot<br />

be determined, call INNOVATION DATA PROCESSING for technical assistance.<br />

<strong>FDR</strong>287 ATTACH ERROR, RC=comp<br />

Reason: <strong>FDR</strong>CONVT could not successfully attach a required subtask. “comp” is the return code,<br />

in hex, from ATTACH.<br />

Action: If the problem cannot be determined from the dump, call INNOVATION DATA<br />

PROCESSING for technical assistance.<br />

<strong>FDR</strong>288 reason catalogname<br />

Reason: <strong>FDR</strong>CONVT encountered an error while trying to find a catalog specified in the INCAT<br />

parameter for the “reason” indicated. If the reason is LOCATE ERROR, the return<br />

code and reason code from CATALOG are displayed; these are documented under<br />

IBM message IDC3009I in the IBM messages manuals.<br />

Action: Correct the error. Specify the correct catalog if necessary. Contact INNOVATION DATA<br />