FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MESSAGES AND CODES<br />
MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />
Action:<br />
STORGRP NOT FOUND OR NO VOLUMES – The storage group is inactive or<br />
contains no active volumes. Determine what storage groups and volumes<br />
are available using ISMF or the operator command:<br />
“D SMS,STORGRP(ALL),LISTVOL”.<br />
STORGRP MORE THAN 255 ACTIVE VOLS – Storage groups with over 255<br />
volumes are not supported by MOUNT STORGRP=.<br />
STORGRP CONTAINS NO ONLINE VOLUMES – The specified storage group<br />
contains no volumes online to the operating system.<br />
ABR bypasses the volumes or storage group specified and continue. If necessary,<br />
corrects the error and resubmits.<br />
<strong>FDR</strong>344 <strong>FDR</strong> FAILED TO FIND THE ABR HIGH LEVEL INDEX<br />
Reason: <strong>FDR</strong>ABR issued a LOCATE (SVC 26) for the ABR high-level index (by default,<br />
<strong>FDR</strong>ABR), however, the alias could not be found.<br />
Reason: Use IDCAMS LISTCAT to list the master catalog and determine if an alias entry exists for the<br />
ABR index. Check the ABR high-level index name specified in the <strong>FDR</strong> Global Options<br />
Table and determine if the name matches the one in the master catalog. If cause cannot<br />
be determined, contact INNOVATION DATA PROCESSING for assistance.<br />
<strong>FDR</strong>345 FILTER ERROR REASON=reason -- ENTRY=entry<br />
Reason: “SELECT CATDSN=filter” was used to select entries from the system catalogs, and an<br />
error occurred. “entry” indicates the catalog name or the catalog entry on which the<br />
error occurred. “reason” indicates the error:<br />
1 NO CATALOGED ENTRIES FOUND – The filter did not select any entries<br />
from the catalogs.<br />
2 CATLG ERROR COMP=cccc CODE=reason – The IBM catalog SVC<br />
returned return code “xxxx” with reason code “reason”. These codes can be<br />
found under message IDC3009I in IBM message manuals.<br />
3 CATLG NAME FPL ADDR MISSING – Internal error.<br />
4 CATLG VOLSER FPL ADDR MISSING – Internal error.<br />
5 CATLG VOLSER 0 OR MORE THAN 20 – A catalog entry was selected that<br />
had either 0 volsers or more than 20 volsers in a CVOL (SYSCTLG) catalog.<br />
6 MAXCARDS MUST BE INCREASED – Since a SELECT statement is<br />
simulated for every data set selected from the catalog, the value of<br />
MAXCARDS= must be large enough to accommodate all selected data sets.<br />
7 CATLG ENTYPE FPL ADDR MISSING – Internal error.<br />
A NAME LAST CHARACTER HIGH VALUES – Internal error.<br />
B VSAM COMPONENTS NOT FOUND – A VSAM cluster was selected from<br />
the catalog but catalog entries for its components were not found.<br />
C VOL= CANNOT BE SPECIFIED – The VOL= operand cannot be specified<br />
on a SELECT CATDSN= statement in a RESTORE operation.<br />
D CANNOT END IN A PERIOD – The filter cannot end in a period. See<br />
Section 80.14 “Generic <strong>Data</strong> Set Name Selection” for filter rules.<br />
E INVALID GENERATION NUMBER – The filter ends in an invalid GDG<br />
relative generation number.<br />
F SEQUENCE ERROR IN CATALOG – A VSAM sequence error was<br />
encountered reading a catalog, indicating a structural error in the catalog.<br />
G ALL ENTRIES EXCLUDED OR DUPS – All catalog entries matching this<br />
filter were discarded because:<br />
– They were excluded by a preceding EXCLUDE statement.<br />
– They were selected by a preceding SELECT CATDSN= statement.<br />
– They specified a volume serial that did not match the VOL=<br />
operand on this SELECT statement.<br />
– They were migrated by DFSMShsm (volser=MIGRAT).<br />
CHAPTER 100 – PAGE 100-74 –