30.01.2015 Views

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FDR</strong>S20**<br />

Reason:<br />

Action:<br />

MESSAGES AND CODES<br />

<strong>FDR</strong>REORG MESSAGES (<strong>FDR</strong>RNN & <strong>FDR</strong>SNN) 100.7<br />

RACF INFORMATION DOES NOT EXIST -- UNABLE TO SUBSTITUTE racfdata<br />

&RACFUID (USER ID) or &RACFGID (GROUP ID) was used with the BACKUPGROUP,<br />

BACKUPINDEX, CKPTPREFIX, LASTAPEPREFIX, or LOGPREFIX keywords and the<br />

user id or group id was missing from the ACEE control block.<br />

If you do not have a security system such as IBM RACF installed, you may be able to<br />

use this feature if you are running MVS/ESA by providing a USER or GROUP<br />

parameter on the JOB card. If you do have a security system, then a system error has<br />

probably occurred. Have the system security administrator or system programmer<br />

check that the appropriate user and group information is being provided.<br />

<strong>FDR</strong>S21** type=UNIT NOT VALID -- operand IS NULL<br />

Reason: The operand BACKUPALLOC=UNIT, CKPTALLOC=UNIT, or LOGALLOC=UNIT<br />

requested dynamic allocation of a data set, but the associated UNIT operand<br />

(BACKUPUNIT=, CKPTUNIT=, or LOGUNIT=) was not specified and defaulted to<br />

NULL.<br />

Action: Set a default value for the appropriate UNIT operand in the <strong>FDR</strong>REORG option table by<br />

running the <strong>FDR</strong>REOZO option table change utility, or specify a value at run time.<br />

<strong>FDR</strong>S22** type =SMS NOT VALID -- operand IS NULL<br />

Reason: The operand BACKUPALLOC=SMS, CKPTALLOC=SMS, or LOGALLOC=SMS<br />

requested dynamic allocation of an SMS-Managed data set, but the associated<br />

STORCLASS operand (BACKUPSTORCLASS=, CKPTSTORCLASS=, or<br />

LOGSTORCLASS=) was not specified and defaulted to NULL.<br />

Action: Set a default value for the appropriate STORCLASS keyword in the <strong>FDR</strong>REORG option<br />

table by running the <strong>FDR</strong>REOZO option table change utility, or specify a value at run<br />

time.<br />

<strong>FDR</strong>S23** BACKUPSTRING REQUIRES AN OLD AND NEW STRING -- SPECIFY<br />

BACKUPSTRING=(OLDSTR,NEWSTR)<br />

Reason: The BACKUPSTRING keyword was coded incorrectly.<br />

Action: Correct the error and rerun the job.<br />

<strong>FDR</strong>S24** REORG OR SIMULATE COMMAND MUST PRECEED statement<br />

Reason: A SELECT or EXCLUDE statement was encountered before a REORG or SIMULATE<br />

statement.<br />

Action: SELECT and EXCLUDE statements must follow a REORG or SIMULATE statement.<br />

Correct the error and rerun the job.<br />

<strong>FDR</strong>S25**<br />

Reason:<br />

<strong>FDR</strong>S26**<br />

Action:<br />

Reason:<br />

Action:<br />

RECOVER COMMAND NOT SUPPORTED AFTER A REORG OR SIMULATE COMMAND<br />

Because of the basic differences in how the checkpoint and log files are used by a<br />

REORG and RECOVER function, it is not possible to perform both functions in a<br />

single execution.<br />

Run the RECOVER function as a separate job or job step.<br />

REORG OR SIMULATE COMMAND NOT SUPPORTED AFTER A RECOVER COMMAND<br />

Because of the basic differences in how the checkpoint and log files are used by a<br />

REORG and RECOVER function, it is not possible to perform both functions in a<br />

single execution.<br />

Run the REORG or SIMULATE function as a separate job or job step.<br />

CHAPTER 100 – PAGE 100-156 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!