FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
MESSAGES AND CODES<br />
MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />
Action:<br />
S<br />
S<br />
S<br />
ANTRQST REQUEST BUFFER EXHAUSTED – An error occurred while<br />
invoking the IBM FlashCopy API. Contact INNOVATION DATA<br />
PROCESSING for assistance.<br />
SOURCE VOLUME NOT IN FLASHCOPY STATUS – An error occurred<br />
while invoking the IBM FlashCopy API. Contact INNOVATION DATA<br />
PROCESSING for assistance.<br />
SRC/TGT VOLUMES NOT PAIRED OR IN SIMPLEX STATE – The<br />
FlashCopy source and target volumes are each already paired with a<br />
different volume OR they are not both in Simplex state. FlashCopy cannot<br />
be used on this pair until those FlashCopy sessions are terminated.<br />
S FLASHCOPY – ANTRQST FUNCTION FAILURE – Unknown error<br />
occurred while attempting to issue the ANTRQST function. Check <strong>FDR</strong>149<br />
message for requested function, return and reason codes.<br />
S FLASHCOPY UNEXPECTED QUERY DATA RETURNED – An error<br />
occurred while invoking the IBM FlashCopy API. Contact IBM to be sure<br />
you have the latest maintenance for FlashCopy and contact INNOVATION<br />
DATA PROCESSING for assistance.<br />
S FLASHCOPY WITHDRAW FUNCTION FAIL CODE=nnnnn-nnnnn<br />
RELEASE BYPASSED – FCOPY=(USE,REL) was specified but the<br />
FlashCopy withdraw (FCWITHDR) failed with the indicated return codes.<br />
T FLASHCOPY VOL(S) ARE IN ACTIVE RELATIONSHIPS – Either the<br />
FlashCopy source or target volume is already paired with a different volume.<br />
FlashCopy cannot be used on this pair until that FlashCopy session is terminated.<br />
T FLASHCOPY ESTABLISH FAILED FOR SOURCE – An attempt to<br />
establish the relationship has failed. Perform FCQUERY on source and<br />
target volumes to determine cause of failure. Review <strong>FDR</strong>149 for<br />
information on current device status, return and reason codes. Check<br />
source and target compatibility and capacity.<br />
T<br />
T<br />
FLASHCOPY RELEASE FAILURE – An attempt to release the relationship<br />
due to the use of FCOPY=(USE,REL) has failed. Review <strong>FDR</strong>149 for<br />
information on current device status, return and reason codes. Possibly due<br />
to the use of FCOPY=COPY or an external FCWITHDR being performed.<br />
ANTRQST - PPRC REQUEST FAILURE – An error occurred while invoking<br />
the IBM PPRC API. Contact INNOVATION DATA PROCESSING for assistance.<br />
U SECURITY ACCESS DENIED TO DSN=<strong>FDR</strong>.USE.UNITxxxx –<br />
<strong>FDR</strong>INSTANT security checking was enabled, and the user id under which<br />
the <strong>FDR</strong>INSTANT request was run does not have UPDATE authority to the<br />
data set <strong>FDR</strong>.USE.UNITxxxx where “xxxx” is the device address of the<br />
offline target volume specified by the xxxxUNIT= operand.<br />
V<br />
W<br />
X<br />
BCVUNIT= IS NOT SPLIT FROM SOURCE DEVICE – WILL SEARCH<br />
UCBS – The device specified by BCVUNIT= was not a BCV split from the<br />
online volume specified by VOL=. <strong>FDR</strong> searches all offline UCBs for the<br />
proper BCV; if found, the operation continues; if not found, another<br />
message is issued and the operation fails.<br />
VOL1 RESERVED FIELDS NOT BLANK – <strong>FDR</strong>INSTANT stores information<br />
in reserved fields in the volume label of the offline volume. This is a warning that<br />
those fields were not blanks, as expected, but ABR overlaid them anyway.<br />
EMCQCAPI ERROR RC=rrrrrrrr ACTION=aa IORC=iiii – An error occurred<br />
invoking the EMC SNAP API. Error codes are displayed. If the API returned a text<br />
explanation of the error, a second line with MSG= is displayed. One common cause<br />
is that the EMCSCF address space is not active.<br />
In most cases, the volume is bypassed. In the case of <strong>FDR</strong>COPY, it may use standard<br />
read/write I/O if an instant replication facility cannot be used. If additional MOUNT<br />
statements were specified, additional volumes are processed.<br />
CHAPTER 100 – PAGE 100-52 –