30.01.2015 Views

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MESSAGES AND CODES<br />

COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />

CPK587W VOL=vvvvvv RECOVERY BYPASSED DUE TO reason<br />

Reason: A Fast COMPAKTion (CPK TYPE=FASTCPK) run on disk volume “vvvvvv” (see<br />

message CPK586W) did not complete. This Fast COMPAKTion job attempted to<br />

recover from the failure but the recovery was unsuccessful for the reason indicated.<br />

Action: The volume is not in a usable state. Many data sets may be unusable. Contact<br />

INNOVATION DATA PROCESSING if you cannot correct the error.<br />

CPK595E<br />

Reason:<br />

Action:<br />

program TERMINATED ABNORMALLY WITH COMP CODE Ssss Uuuuu<br />

A COMPAKTOR subtask abnormally terminated with either a system ABEND code “sss” (in<br />

HEX), or a user ABEND code “uuuu” (in decimal). “program” is <strong>FDR</strong> for an <strong>FDR</strong> full-volume<br />

backup (DUMP=YES) or <strong>FDR</strong>RESTR for the actual modification of the volume.<br />

For SYSTEM ABENDs, refer to the appropriate IBM System Codes Manual. For user<br />

ABENDs, look it up in Section 100.8 “ABEND Codes”. If the module is <strong>FDR</strong>, no changes<br />

were made to the volume, but if it is <strong>FDR</strong>RESTR and message CPK321I was printed<br />

without CPK403E the volume may be unusable. If possible, correct the error and rerun.<br />

Contact INNOVATION DATA PROCESSING for assistance.<br />

CPK600In COMPAKTOR status type RUN -- VOL=vvvvvv<br />

Reason: Informs you of the status of the run. “type” is the type of run: MAPPING, SIMULATION,<br />

RELEASE, or COMPAKTION. “status” is SUCCESSFULLY COMPLETED or<br />

COMPLETED WITH ERRORS; in the latter case, some warning messages were<br />

issued but the COMPAKTion was able to complete. “n” is an internal code indicating<br />

the volume reorganization algorithm was used to position the data sets.<br />

CPK601I RESTORED DEVICE IS UNIT=uuuu,VOLSER=vvvvvv,DEVTYPE=ddddddd<br />

Reason: Identifies the COMPAKTed volume if an output disk was modified.<br />

CPK602A SERIOUS ERROR(S) DETECTED. COMPAKTOR ABENDING<br />

Reason: One or more previous error messages were issued and COMPAKTOR terminates<br />

abnormally.<br />

Action: See the Action for the other error messages.<br />

CPK603A COMPAKTOR RESTORE CANCELLED reason<br />

Reason: The COMPAKTion of the current volume was bypassed because:<br />

SYSTEM RESIDENCE VOLUME – You cannot COMPAKT the current SYSRES<br />

(IPL volume).<br />

BY CONSOLE OPERATOR – The operator replied “NO” to the <strong>FDR</strong>W80 WTOR<br />

message.<br />

CPK604W<br />

Reason:<br />

COMPAKTOR OPERATION TERMINATED BY CANCEL COMMAND -- REMAINING<br />

VOLUMES BYPASSED<br />

The operator attempted to cancel the COMPAKTOR job and it was intercepted by<br />

COMPAKTOR CANCEL protection. The operator then replied “S” to the <strong>FDR</strong>W99<br />

message, causing COMPAKTOR to terminate after completing processing on the<br />

current volume. If more volumes were to be processed in the step, they are bypassed.<br />

CPK605W COMPAKTOR ABENDING DUE TO EXCEEDING MAXIO<br />

Reason: COMPAKTOR terminates due to exceeding MAXIO.<br />

CPK606E SNAPSHOT REQUEST ERROR - reason<br />

Reason: FAST COMPAKTOR was executed with SNAPSHOT=YES, but an error occurred while<br />

using SnapShot on an IBM RVA or Oracle StorageTek disk. “reason” details the error.<br />

Action: Contact INNOVATION DATA PROCESSING Technical Support.<br />

CHAPTER 100 – PAGE 100-142 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!