MESSAGES AND CODES<br />

<strong>FDR</strong> CONSOLE MESSAGES AND TSO TERMINAL MESSAGES 100.2<br />

<strong>FDR</strong>W25 ABR REQUEST FOR TAPES(nn) vvvvvv... REPLY YES NO OR BYPASS(nn)<br />

Reason: The OPERATOR operand was specified on a RESTORE statement for a full-volume<br />

ABR RESTORE. Message <strong>FDR</strong>W25 is repeated for each ABR Volume Backup that is<br />

used during the restore; each line shows the ABR Cycle number “nn” followed by the<br />

volume serials of the backups “vvvvvv…” required for that cycle.<br />

Action: Reply “YES” – All of the volumes are available.<br />

Reply “NO” – All or some volumes are not available. The restore request is cancelled.<br />

Reply “BYPASS(nn)” – The tapes shown for cycle “nn” are not be used during the restore. “nn”<br />

may be any cycle that was listed, except cycle zero (the full volume backup). After a reply of<br />

BYPASS(nn), the message is reissued so that additional backups can be bypassed. When all<br />

desired backups to be bypassed have been specified, reply “YES”. <strong>Data</strong> sets whose latest<br />

backup was on the cycles that you bypassed are probably not correctly restored.<br />

<strong>FDR</strong>W26 INVALID RESPONSE REPLY YES NO OR BYPASS(nn)<br />

Reason: The operator reply to message <strong>FDR</strong>W25 was invalid. Either, the operator reply was an invalid<br />

keyword, the cycle number was invalid or did not exist, or the cycle number was zero.<br />

<strong>FDR</strong>W27<br />

Action:<br />

Reason:<br />

Action:<br />

Give a proper response to the message.<br />

REPLY WAIT, NOWAIT, OR RETRY FOR ENQ WAIT ON DSN=dsname<br />

An <strong>FDR</strong> job specified DSNENQ=HAVE. <strong>Data</strong> set “dsname” is currently enqueued to another job.<br />

Reply “WAIT” – <strong>FDR</strong> waits for the data set to become available. The job could time out if<br />

the enqueue is not released in a short time.<br />

Reply “NOWAIT” – <strong>FDR</strong> issues an <strong>FDR</strong>158 warning message for the data set.<br />

❖ For DUMP, the data set is dumped unless ENQERR=BYPASS is specified.<br />

❖ For Archive or Superscratch, the data set is bypassed.<br />

❖ For RESTORE, the data set is bypassed.<br />

❖ For COMPAKTOR, the data set is made unmovable.<br />

Reply “RETRY” – <strong>FDR</strong> retries the enqueue. If it is still not available, message <strong>FDR</strong>W27 is re-issued.<br />

<strong>FDR</strong>W40 MODULE modname INSTALLED AT address -- VER v.r<br />

Reason: The message is issued in response to a status request when the <strong>FDR</strong> operating system<br />

exit module “modname” is installed in the system. “address” is the virtual storage<br />

location of that module. The version number of the module is also given.<br />

Reason:<br />

<strong>FDR</strong> GLOBAL OPTIONS LOADED AT hh:ss ON yy.ddd FROM VOL=volser DSN=loadlibrary<br />

The message is issued when an <strong>FDR</strong> operating system exit is installed or in response to<br />

a status request. It shows the when the memory-resident copy of the <strong>FDR</strong> option table<br />

(<strong>FDR</strong>OPT) was loaded and from which load library.<br />

<strong>FDR</strong>W41 THE <strong>FDR</strong> SYSTEM MODULES ARE status -- VER nn type<br />

Reason: This message is issued by <strong>FDR</strong>START or <strong>FDR</strong>STATS when the <strong>FDR</strong> operating system<br />

exit modules are installed in the system.<br />

The “status” of the modules may be:<br />

ACTIVE – On the first execution of <strong>FDR</strong>START or on executions of <strong>FDR</strong>STATS;<br />

RE-ACTIVATED – On executions of <strong>FDR</strong>START where an <strong>FDR</strong> operating system<br />

exit module was re-activated.<br />

REFRESHED – On subsequent executions of <strong>FDR</strong>START where the copy of the<br />

<strong>FDR</strong> Global Options Table module in global storage was refreshed.<br />

This message includes the version and release level of the modules installed.<br />

“type” may indicate:<br />

PROD – For production exits.<br />

TEST – For test exits (the JOBNAME= or JOBGROUP= that uses the test exists is<br />

also displayed).<br />

CHAPTER 100 – PAGE 100-5 –