MESSAGES AND CODES<br />
COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />
CPK541W FORMAT n DSCBS LEAVE nnnnnnnn TRACKS UNACCOUNTED FOR<br />
Reason: Some tracks are not allocated to any data set are not described by any Format 5 or<br />
Format 7 DSCB.<br />
Action: If you are actually COMPAKTing the volume, COMPAKTOR automatically creates<br />
accurate Format 5/7 DSCBs.<br />
CPK542E<br />
Reason:<br />
CPK543W<br />
Action:<br />
Reason:<br />
Action:<br />
UNABLE TO HONOR REQUEST TO ALTER VTOC POSITION OR SIZE. VSAM DATA<br />
SETS EXIST ON VOLUME<br />
A SELECT ***VTOC statement was input but non-ICF VSAM clusters with non-zero<br />
secondary allocation quantities exist on volume to be COMPAKTed.<br />
Remove the SELECT statement; or, if you need to alter the size or location of the VTOC<br />
on this volume, you must first EXPORT all objects in VSAM data spaces with non-zero<br />
secondary allocation quantities, and DELETE the data spaces. After COMPAKTion,<br />
you can IMPORT the objects.<br />
INVALID REQUEST TO CHANGE VTOC POSITION OR SIZE. VSAM DATA SETS<br />
EXIST ON VOLUME. SIMULATION WILL CONTINUE<br />
A SELECT ***VTOC statement was input but non-ICF VSAM clusters with non-zero<br />
secondary allocation quantities exist on source volume.<br />
COMPAKTOR continues the simulation and performs any requested VTOC position or size<br />
changes. However, this message is to warn you that your request to alter the VTOC’s<br />
position or size is not honored during a real COMPAKTion (message CPK542E).<br />
CPK552E THE FOLLOWING DATA SET IS INELIGIBLE FOR POSITIONING -- dsname<br />
IT IS EITHER UNMOVABLE, HAS A STANDARD-USER LABEL, OR GIVEN CCHH<br />
POSITION IS INVALID FOR THIS DATA SET.<br />
Reason: The data set “dsname” was named on a SELECT statement with POS= specified or included<br />
in a sequence set with POS=. The positioning requested is not possible because:<br />
❖ It is marked as unmovable.<br />
❖ It has a user labels (LABEL=(,SUL)).<br />
CPK553E<br />
Action:<br />
Reason:<br />
Action:<br />
❖<br />
❖<br />
It must be on a cylinder boundary but the given position is not on such a boundary.<br />
It was positioned so that, while its first track was within the capacity of the volume, one<br />
or more tracks at the end of the data set were outside the volume track boundaries.<br />
Correct the error and rerun.<br />
ONE OR MORE ABSOLUTE POSITIONED OR ACTIVE DATASETS OR VTOCSIZE<br />
OVERLAP A DATA SET AT CCCC.CCCH(HEX) -- ccccc.ccch<br />
One or more SELECT or SEQ statements requested absolute positioning for data sets<br />
(POS=) but it could not be honored because:<br />
❖ A data set would overlap an unmovable or previously positioned data set.<br />
❖ If the cylinder/head address is beyond the end of the volume, then a data set or a<br />
sequenced set of data sets was positioned so that its end was outside the<br />
boundaries of the volume.<br />
“cccc.ccch” is the cylinder and track numbers (in hex) of the data set that would be<br />
overlapped.<br />
Consult the extents map produced by COMPAKTOR and fix your control statements<br />
CPK554E UNABLE TO COMPAKT THIS VOLUME - REASON=reason<br />
Reason: COMPAKTOR was unable to process the volume for “reason” that may be:<br />