MESSAGES AND CODES<br />

COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />

CPK541W FORMAT n DSCBS LEAVE nnnnnnnn TRACKS UNACCOUNTED FOR<br />

Reason: Some tracks are not allocated to any data set are not described by any Format 5 or<br />

Format 7 DSCB.<br />

Action: If you are actually COMPAKTing the volume, COMPAKTOR automatically creates<br />

accurate Format 5/7 DSCBs.<br />

CPK542E<br />

Reason:<br />

CPK543W<br />

Action:<br />

Reason:<br />

Action:<br />

UNABLE TO HONOR REQUEST TO ALTER VTOC POSITION OR SIZE. VSAM DATA<br />

SETS EXIST ON VOLUME<br />

A SELECT ***VTOC statement was input but non-ICF VSAM clusters with non-zero<br />

secondary allocation quantities exist on volume to be COMPAKTed.<br />

Remove the SELECT statement; or, if you need to alter the size or location of the VTOC<br />

on this volume, you must first EXPORT all objects in VSAM data spaces with non-zero<br />

secondary allocation quantities, and DELETE the data spaces. After COMPAKTion,<br />

you can IMPORT the objects.<br />

INVALID REQUEST TO CHANGE VTOC POSITION OR SIZE. VSAM DATA SETS<br />

EXIST ON VOLUME. SIMULATION WILL CONTINUE<br />

A SELECT ***VTOC statement was input but non-ICF VSAM clusters with non-zero<br />

secondary allocation quantities exist on source volume.<br />

COMPAKTOR continues the simulation and performs any requested VTOC position or size<br />

changes. However, this message is to warn you that your request to alter the VTOC’s<br />

position or size is not honored during a real COMPAKTion (message CPK542E).<br />

CPK552E THE FOLLOWING DATA SET IS INELIGIBLE FOR POSITIONING -- dsname<br />

IT IS EITHER UNMOVABLE, HAS A STANDARD-USER LABEL, OR GIVEN CCHH<br />

POSITION IS INVALID FOR THIS DATA SET.<br />

Reason: The data set “dsname” was named on a SELECT statement with POS= specified or included<br />

in a sequence set with POS=. The positioning requested is not possible because:<br />

❖ It is marked as unmovable.<br />

❖ It has a user labels (LABEL=(,SUL)).<br />

CPK553E<br />

Action:<br />

Reason:<br />

Action:<br />

❖<br />

❖<br />

It must be on a cylinder boundary but the given position is not on such a boundary.<br />

It was positioned so that, while its first track was within the capacity of the volume, one<br />

or more tracks at the end of the data set were outside the volume track boundaries.<br />

Correct the error and rerun.<br />

ONE OR MORE ABSOLUTE POSITIONED OR ACTIVE DATASETS OR VTOCSIZE<br />

OVERLAP A DATA SET AT CCCC.CCCH(HEX) -- ccccc.ccch<br />

One or more SELECT or SEQ statements requested absolute positioning for data sets<br />

(POS=) but it could not be honored because:<br />

❖ A data set would overlap an unmovable or previously positioned data set.<br />

❖ If the cylinder/head address is beyond the end of the volume, then a data set or a<br />

sequenced set of data sets was positioned so that its end was outside the<br />

boundaries of the volume.<br />

“cccc.ccch” is the cylinder and track numbers (in hex) of the data set that would be<br />

overlapped.<br />

Consult the extents map produced by COMPAKTOR and fix your control statements<br />

CPK554E UNABLE TO COMPAKT THIS VOLUME - REASON=reason<br />

Reason: COMPAKTOR was unable to process the volume for “reason” that may be:<br />

CHAPTER 100 – PAGE 100-137 –