MESSAGES AND CODES<br />
ABEND CODES 100.8<br />
U0659<br />
U0701<br />
INTERNAL LOGIC ERROR<br />
ERROR IN COMPAKTOR REBUILD OF INDEXED VTOC OR UPDATE OF VVDS<br />
U0777 INTERNAL PROGRAM ERROR, ENVIRONMENT ERROR OR USER ERROR<br />
Reason: Some possible causes are:<br />
❖ A module was called by a module from a different version or level.<br />
❖ A module received an invalid parameter list.<br />
❖ A TSO-only module was executed in batch.<br />
❖ An unexpected error was encountered in an operating system routine.<br />
❖ The input file being processed was not a valid <strong>FDR</strong>ABR backup name.<br />
Contact INNOVATION DATA PROCESSING Technical Support for assistance.<br />
U0801 RESTORE CANCELLED BY OPERATOR OR SECURITY FAILURE<br />
Reason: This ABEND can also be issued for other errors as described by messages in the listing. For<br />
an ABR SNAP or SPLIT with DSNENQ=, a data set was found to be in use by another task<br />
(message <strong>FDR</strong>158) so the SNAP or SPLIT is cancelled. Specify ENQERR=NO on the<br />
SNAP or SPLIT statement if you want to create the point-in-time backup anyway.<br />
U0802 INVALID COMPLETION CODE FROM AN USER EXIT<br />
Reason: A parameter passed back by an user security exit was invalid.<br />
U0803 ERROR IN <strong>FDR</strong>CRYPT (ENCRYPTION OR DECRYPTION)<br />
Reason: A non-recoverable error occurred in <strong>FDR</strong>CRYPT; see other messages for details.<br />
U0804 ERROR IN DE-COMPRESSION<br />
Reason: A non-recoverable error, probably due to bad data, occurred while de-compressing a<br />
compressed <strong>FDR</strong> data block. This can occur if a backup encrypted with <strong>FDR</strong>CRYPT<br />
is restored using a library that does not have <strong>FDR</strong>CRYPT.<br />
U0805 <strong>FDR</strong>INSTANT PROCESS TERMINATED ABNORMALLY<br />
Reason: The <strong>FDR</strong>INSTANT process detected an abnormal situation and cannot continue. The<br />
<strong>FDR</strong>INSTANT process terminated itself. Preceding <strong>FDR</strong>nnn messages describe the<br />
reason for this abnormal termination.<br />
U0887 MESSAGE <strong>FDR</strong>321 REASON=E OR M WAS ISSUED<br />
Reason: An ABEND was forced by the DEBUG option.<br />
U0888 A NON-TERMINATING ERROR OCCURRED<br />
Reason: One or more <strong>FDR</strong>, DSF, <strong>FDR</strong>COPY, ABR, or COMPAKTOR operations abnormally<br />
terminated or ended with diagnostic messages, but the errors were not severe enough<br />
to prematurely terminate the entire step. This ABEND is issued to call attention to the<br />
errors. Examine the printout for the error messages causing this ABEND.<br />
If a subtask abnormally terminated, the real ABEND code is printed in the storage dump<br />
and in the <strong>FDR</strong>319 message. <strong>FDR</strong>, DSF, <strong>FDR</strong>COPY, and COMPAKTOR issue this<br />
ABEND by default when non-terminating errors occur, but the ABEND can be<br />
changed to a return code by updating the <strong>FDR</strong> Global Options Table. ABR issues a<br />
return code of 12 in this case, by default, but it can be changed in the option table to<br />
issue the U0888 ABEND instead.<br />
CHAPTER 100 – PAGE 100-167 –