<strong>FDR</strong>927<br />

Reason:<br />

Action:<br />

MESSAGES AND CODES<br />

MESSAGES FROM SAR (<strong>FDR</strong>9NN) 100.4<br />

ENTER ABSOLUTE TRACK ADDRESS IN DECIMAL - ENTER ***END TO PROCESS<br />

You requested an absolute track operation. The message “STARTING CCHH=CCCCCHHHH” is<br />

displayed.<br />

Replace the CCCCCHHHH with the cylinder (5 digits) and head/track (4 digits) in decimal.<br />

After ENTER is depressed, SAR displays the ENDING CCHH= message; the ending<br />

cylinder and head/track is then entered. Up to 10 absolute ranges may be specified. When<br />

the last range is entered, reply “***END” to the STARTING CCHH= message.<br />

<strong>FDR</strong>928 MAXIMUM NUMBER OF ENTRIES EXCEEDED - ENTER ***END TO PROCESS<br />

Reason: You have entered the maximum number of entries (10) for data set names or absolute<br />

track ranges.<br />

Action: You must enter “***END” for SAR to process the data sets or tracks specified.<br />

<strong>FDR</strong>929 RESTORED CYL=cccc TRK - 0....5....ABCDEF0....5....ABCDEF<br />

Reason: On absolute track operations, SAR displays each cylinder processed (“cccc” is the<br />

cylinder number in hex). An “X” is printed in the appropriate column for each track<br />

restored within the cylinder.<br />

<strong>FDR</strong>930 TRACK TABLE ERROR<br />

Reason: A cylinder and head address was encountered on the backup tape that exceeded the<br />

track capacity of the disk volume.<br />

Action: If a hardcopy device was assigned, use the hardware PSW RESTART function to take a<br />

storage dump. Contact INNOVATION DATA PROCESSING for assistance.<br />

<strong>FDR</strong>931 VALID RESPONSE=responses<br />

Reason: This is an informative message to indicate the responses that are valid for the current<br />

console message. SAR may not display all of the possible responses. Chapter 30<br />

“<strong>FDR</strong>REORG®” of the <strong>FDR</strong> manual details all of the allowed responses to a message.<br />

Action: Enter the appropriate response.<br />

VALID RESPONSE=xxxxxx -- IDENTIFIED BY SAR<br />

Reason: The device type “xxxxxx” was determined by SAR to be the actual type of the disk<br />

device you input. It should not be overridden, except as discussed under “Alternate<br />

Device Support” in Section 15.1 “SAR Technical Description”.<br />

<strong>FDR</strong>932 I/O ERROR ON DISK TRACK X'cccchhhh' - REPLY CONTINUE OR TERM<br />

Reason: A logical or physical hardware error occurred on the disk track at cylinder “cccc” and<br />

track “hhhh” (in hex). A <strong>FDR</strong>951-<strong>FDR</strong>990 error message may have been displayed<br />

detailing the error. SAR did not backup or restore the indicated track properly.<br />

Action:<br />

SAR prompts you for a reply. Reply “CONTINUE” to ignore the error and continue with the next<br />

disk track (the contents of the bad track is not dumped or may be improperly restored), or<br />

“TERM” to terminate SAR with an error. If you have a hardcopy device assigned, you can use<br />

the hardware PSW RESTART function to take a storage dump before replying.<br />

<strong>FDR</strong>933 TAPE MOUNTED FOR usage status DSN=dsname<br />

REPLY YES FOR SAR TO USE IT AS type - NO TO REJECT - EXPDT=yyddd<br />

Reason: SAR displays the current data set name (last 17 characters from the tape label) for each<br />

tape mounted. “usage” may be HARDCPY, DUMP, or RESTORE.<br />

“status” indicates whether SAR detected labels on the tape and can be:<br />

IS VOL=vvvvvv – For a labeled tape.<br />

CHAPTER 100 – PAGE 100-119 –