MESSAGES AND CODES<br />

MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />

Action:<br />

– They were archived by ABR and recataloged for Auto-recall.<br />

NOTE: If you have volumes with VTOCs located above relative track 32767, CATDSN=<br />

thinks that data sets on those volumes are cataloged for recall and does not select<br />

them. INNOVATION DATA PROCESSING recommends that such VTOCs be<br />

relocated lower on the volume; COMPAKTOR can do this.<br />

J INSUFFICENT STORAGE – The REGION size was not large enough.<br />

Increase the REGION (use REGION=0M if you can) and resubmit.<br />

K ABR BACKUP NOT FOUND VOL=vvvvvv – The ABR backup file for a<br />

cloned data set was not found in the ABR catalog. The current backup of a<br />

selected data set is no longer recorded.<br />

Serious errors cause an U0502 ABEND. Others (such as reason “1”) are simply treated as if<br />

a SELECT statement did not select any data sets, unless SELTERR=NO was specified.<br />

<strong>FDR</strong>346<br />

Reason:<br />

FILTER SELECTED VOL=volser DSN=dsname<br />

FILTER SELECTED ALIAS=alias CAT=catalog TIME=hhmmss<br />

FILTER SELECTED nnnnnnnn ENTRIES in sssss.ss SECONDS<br />

A filter was used to select entries from the system catalogs. The first form of the <strong>FDR</strong>346<br />

message is displayed only if PCATDSN= is used (instead of CATDSN=) and indicates<br />

each data set name selected from the catalog and the volser it is cataloged on.<br />

The second form of the <strong>FDR</strong>346 message is displayed only if the PRTALIAS operand is<br />

specified, and indicates each alias that is selected from the master catalog by the filter<br />

and the name of the user catalog that was searched for it (even if no data sets are<br />

selected in that alias).<br />

The third form of the <strong>FDR</strong>346 message documents the number of entries selected by<br />

the filter, and the elapsed time in seconds required to complete the search.<br />

<strong>FDR</strong>347 SMS MGMTCLAS ERROR VOL=volser REASON=reason DSN=dsname<br />

Reason: SMSMANAGE=YES was specified, but an error occurred trying to use SMS<br />

management classes for ABR processing. “volser” identifies the volume being<br />

processed (if known) and “dsname” identifies the data set being processed for errors<br />

related to a particular data set. “reason” describes the error:<br />

GETMAIN FAILURE -- MGMTCLAS DISABLED – Indicates that the GETMAIN for<br />

storage above the 16M line to hold the definitions of all active management<br />

classes failed. Management class processing is disabled.<br />

NVR/VVR TYPE UNKNOWN – A VVDS record was not type N, Z, or Q. The VVDS<br />

may be damaged.<br />

TYPE 21 NOT FOUND – The type 21 cell was not found in a VSAM VVR. The<br />

VVDS may be damaged.<br />

TYPE 22 NOT FOUND – The type 22 sub-cell was not found in a non-VSAM NVR.<br />

The VVDS may be damaged.<br />

TYPE 23 NOT FOUND – The type 23 cell was not found in a VSAM VVR. The<br />

VVDS may be damaged.<br />

TYPE 24 NOT FOUND – The type 24 cell was not found in a non-VSAM NVR. The<br />

VVDS may be damaged.<br />

MGMTCLAS INVALID – The management class name in the NVR/VVR of an<br />

SMS-Managed data set (or the default management class name) is not<br />

currently defined to SMS.<br />

NO MGMTCLAS TABLE – Internal error.<br />

NO VVDS ENTRY – No NVR/VVR was found in the VVDS for an SMS-Managed<br />

data set. The VVDS or the VTOC may be damaged, or creation of an<br />

SMS-Managed data set was interrupted.<br />