FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
MESSAGES AND CODES<br />
COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />
Action:<br />
RECOVERY LOG FULL – The FASTCPK recovery log is full. More tracks were<br />
moved than can be recorded in the recovery log. Remove operands that<br />
cause many tracks to be moved (such as SIZEKEEP=0,<br />
OBJECT=MINEXTS, DATA=ALL, and POS=) and rerun. Can occur if the<br />
volume has few free space areas before COMPAKTion; you can add<br />
CPKFREEX=nn to avoid COMPAKTing such volumes. FASTCPK will go<br />
into recovery and return the volume to its previous state.<br />
INSUFFICIENT FREE STORAGE TRACKS - VOLUME NOT CHANGED – There<br />
are too few unallocated tracks on the volume for FASTCPK to successfully<br />
operate. The U0888 ABEND can be suppressed for this “reason” by adding<br />
UNABLE=IGNORE on the CPK statement.<br />
NO FREE DSCB FOR RECOVERY LOG - VOLUME NOT CHANGED – There are<br />
no free Format 0 DSCBs in the VTOC. FASTCPK requires at least one free<br />
DSCB for its recovery log. The U0888 ABEND can be suppressed for this<br />
“reason” by adding UNABLE=IGNORE on the CPK statement.<br />
NO FREE TRACK FOR RECOVERY LOG - VOLUME NOT CHANGED – There is<br />
no track on the volume that will be in free space both before and after the<br />
FASTCPK. FASTCPK requires at least one such track for its recovery log.<br />
The U0888 ABEND can be suppressed for this “reason” by adding<br />
UNABLE=IGNORE on the CPK statement.<br />
ALGORITHMS FAILED - VOLUME NOT CHANGED – None of the internal<br />
repositioning algorithms used by COMPAKTOR was able to develop a new<br />
layout for the volume. This usually occurs when you use POS= to position data<br />
sets or have a large number of unmovable or active data sets and<br />
COMPAKTOR was unable to find a location for a large data set. Reduce the<br />
number of POS= operands and rerun. The U0888 ABEND can be suppressed<br />
for this “reason” by adding UNABLE=IGNORE on the CPK statement.<br />
INSUFFICIENT STORAGE - VOLUME NOT CHANGED – The region was insufficient<br />
for FASTCPK. Increase the region size.<br />
I/O ERROR - VOLUME NOT CHANGED – An I/O error occurred on the output<br />
volume during initialization.<br />
I/O ERROR WRITING RECOVERY LOG - VOLUME NOT CHANGED – An I/O error<br />
occurred formatting the FASTCPK recovery log.<br />
NON-STANDARD DATA SET NAME - VOLUME NOT CHANGED – The VTOC of<br />
the volume contains a data set with a non-standard data set name, such as imbedded<br />
blanks or non-standard characters. FASTCPK cannot handle such data sets.<br />
An U0888 ABEND or non-zero return code will be issued at step end to call attention to<br />
the error. Except for RECOVERY LOG FULL, the volume has not been changed; if<br />
you can correct the error, rerun the job.<br />
For RECOVERY LOG FULL, COMPAKTOR reverses the tracks already moved,<br />
returning the volume to its original state. If the recovery fails, contact INNOVATION<br />
DATA PROCESSING for assistance.<br />
CPK555E VTOC TOO SMALL TO HOLD ALL DSCBS. INCREASE VTOC SIZE AND RETRY.<br />
Reason: On a COMPAKT-from-backup, you changed the size of the VTOC (SELECT ***VTOC,SIZE=nnn),<br />
but it is now too small for all the DSCBs that must be restored into it.<br />
Action:<br />
Reason:<br />
Action:<br />
Consult the summary map output by COMPAKTOR to determine the minimum VTOC<br />
size you require. Correct control statement in error and rerun. Unless you are sure<br />
that no new data sets are allocated on this volume, you should leave a generous<br />
amount of free space in the VTOC.<br />
VTOC SIZE OVERRIDE MUST BE RUN UNDER <strong>FDR</strong>PAS<br />
VTOC SIZE OVERRIDE NOT SPECIFIED UNDER <strong>FDR</strong>PAS<br />
The parameters passed to COMPAKTOR from the EXPANDVTOC keyword in <strong>FDR</strong>PAS<br />
were overridden by the user.<br />
Remove the COMPAKTOR overrides so the parameters specified by <strong>FDR</strong>PAS are used.<br />
CHAPTER 100 – PAGE 100-138 –