30.01.2015 Views

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

FDR V54L78 - Innovation Data Processing

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MESSAGES AND CODES<br />

COMPAKTOR MESSAGES (CPKNNNXX) 100.6<br />

CPK429E INPUT DEVICE ON UNIT=uuuu,VOLSER=vvvvvv IS NOT SUPPORTED BY process<br />

Reason: An unsupported disk device was referenced for COMPAKTOR or TYPE=FASTCPK.<br />

See Section 2.10 “<strong>FDR</strong> Functions and Features” for a list of supported device types. If<br />

TYPE=FASTCPK is printed, the disk control unit is an old model that does not support<br />

the commands used by Fast Compaktion.<br />

Action: Contact INNOVATION DATA PROCESSING for technical assistance.<br />

CPK430E<br />

Reason:<br />

Action:<br />

THE DEVICE TO RESTORE TO -- devtype1 reason THE INPUT DEVICE -- devtype2<br />

When doing a COMPAKT-from-backup, and the output disk (type “devtype1”) is not the<br />

same as the input disk (“devtype2”) the disks are incompatible devices. “reason” may be:<br />

IS INCOMPATIBLE WITH – The disks are different device types (e.g., 3380 and 3390).<br />

IS SMALLER THAN EAV – The disks are the same type, but the input is an EAV and<br />

the output is not. An EAV volume cannot be restored to a non-EAV volume.<br />

IS SMALLER THAN – The disks are the same type but the output disk is smaller than the<br />

input. This is a warning; as long as all the data fits on the output disk and there are<br />

no unmovable data sets above the end of the output disk, the run is successful.<br />

Retry with a valid device as the target device.<br />

CPK431E ERROR TRYING TO DETERMINE DEVICE TYPE<br />

Reason: A DEVTYPE SVC issued to verify the device type received a non-zero return code.<br />

Action: Contact INNOVATION DATA PROCESSING for technical assistance.<br />

CPK432E ’SIZE=nnnnn’ IS TOO LARGE<br />

Reason: The specified new VTOC size “nnnnn” is excessively large.<br />

Action: Correct the error and rerun.<br />

CPK433E INVALID CCHH POSITION SPECIFIED -- ccccchhhh<br />

Reason: A POS= operand was specified with a track address but<br />

❖ The cylinder address “ccccc” is invalid. It exceeds the device capacity.<br />

❖ The track address “hhhh” is invalid. It exceeds the maximum number of tracks per<br />

cylinder.<br />

❖ The given value is all zeroes.<br />

Action: Correct the invalid address and rerun.<br />

CPK451E INVALID CONTINUATION OF A QUOTED STRING.<br />

Reason: A quoted string was improperly continued onto the following control statement. It does<br />

not start at column 16 of the continuation statement.<br />

Action: Correct the error and rerun.<br />

CPK452E EXPECTED CONTINUATION CARD NOT RECEIVED.<br />

Reason: Continuation was indicated on a control statement, but no further control statements<br />

followed.<br />

Action: Correct the error and rerun.<br />

CPK453E CONTINUATION COLUMN IS NON-BLANK, BUT LAST PARAMETER DOES NOT<br />

END WITH A COMMA OR IN COLUMN 071.<br />

Reason: See rules for “Continuing an Operand Field” in Section 1.2.<br />

Action: Correct the error and rerun.<br />

CPK454E INTERNAL PROGRAM ERROR. CALL VENDOR FOR ASSISTANCE<br />

Reason: Program software error.<br />

Action: Contact INNOVATION DATA PROCESSING for assistance.<br />

CHAPTER 100 – PAGE 100-128 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!