MESSAGES AND CODES<br />
<strong>FDR</strong> CONSOLE MESSAGES AND TSO TERMINAL MESSAGES 100.2<br />
Action:<br />
15 modname HAS SMP INSTALLED IDP MODULE – <strong>FDR</strong>START detected<br />
the presence of an ABR operating system exit installed via SMP in the<br />
named module. The ABR operating system exits that are SMP installed<br />
must be removed if they are to be dynamically installed.<br />
16 UNABLE TO OBTAIN CMS LOCK – Call INNOVATION DATA PROCESSING.<br />
17 FREEMAIN ERROR – Call INNOVATION DATA PROCESSING.<br />
18 UNABLE TO OBTAIN LOCAL LOCK – Call INNOVATION DATA<br />
PROCESSING.<br />
19 modname CDE NOT FOUND – Call INNOVATION DATA PROCESSING.<br />
20 {ENQUEUE/DEQUEUE} ERROR ON IAM RESOURCE –<br />
21 {ENQUEUE/DEQUEUE} ERROR ON SYSZSVC – Call INNOVATION<br />
DATA PROCESSING.<br />
22 INVALID VECTOR TABLE STATUS – Call INNOVATION DATA PROCESSING.<br />
23 INVALID VECTOR TABLE CDE ADDRESS – Call INNOVATION DATA<br />
PROCESSING.<br />
24 RC= xxxx FROM SVCUPDTE – Call INNOVATION DATA PROCESSING.<br />
25 NO MODULES TO INSTALL - <strong>FDR</strong>OPT – The dynamic installation options<br />
that indicate which of the ABR operating system exits are to be installed<br />
specified that none of the exits is to be installed. These options (ABRLOC,<br />
ABRDSNF, ABRPRE, and IEBCOPY) are set in the <strong>FDR</strong> Global Options Table,<br />
module <strong>FDR</strong>OPT, using the ABR Install dialog (ISPF panel A.I.4.11.1).<br />
26 <strong>FDR</strong> SYSTEM MODULES INSTALL CANCELLED – This message is<br />
displayed when the console operator replies “NO” to the <strong>FDR</strong>W47 message.<br />
27 modname AND IAMVECTB ARE OUT OF SYNCH –<br />
28 VECTOR TABLE CANNOT BE STOPPED –<br />
29 <strong>FDR</strong>OPT MODULE LEVEL IS NOT HIGH ENOUGH – The dynamic<br />
installation options are not present in the level of <strong>FDR</strong>OPT that was loaded.<br />
30 PARM (PROD OR TEST) NOT SPECIFIED –<br />
31 HIGHER LEVEL OF VIF ALREADY ACTIVE –<br />
32 modname ERROR – Call INNOVATION DATA PROCESSING.<br />
33 modname ERROR – Call INNOVATION DATA PROCESSING.<br />
34 SYSEVENT DONTSWAP ERROR – Call INNOVATION DATA PROCESSING.<br />
35 PROGRAM LEVEL LOWER THAN VECTOR TABLE – Call INNOVATION<br />
DATA PROCESSING.<br />
36 VECTOR TABLE TO BE REPLACED NOT FOUND – Call INNOVATION<br />
DATA PROCESSING.<br />
37 TBL LEVEL NOT HIGH ENOUGH FOR REPLACE – Call INNOVATION<br />
DATA PROCESSING.<br />
38 modname - CSVDYLPA RC=xxxx-xxxxxxxx – Call INNOVATION DATA<br />
PROCESSING.<br />
39 modname NOT FOUND – Call INNOVATION DATA PROCESSING.<br />
40 modname {ENQUEUE/DEQUEUE} ERROR ON SYSZCSV/CSVDYLPA –<br />
Call INNOVATION DATA PROCESSING.<br />
41 modname INSTALLING <strong>FDR</strong>019VM – Call INNOVATION DATA<br />
PROCESSING.<br />
42 modname - CSVDYNEX RC=xxxx-xxxxxxxx – Call INNOVATION DATA<br />
PROCESSING.<br />
If error cannot be determined, contact INNOVATION DATA PROCESSING for assistance.<br />
CHAPTER 100 – PAGE 100-7 –