MESSAGES AND CODES<br />

<strong>FDR</strong> CONSOLE MESSAGES AND TSO TERMINAL MESSAGES 100.2<br />

Action:<br />

15 modname HAS SMP INSTALLED IDP MODULE – <strong>FDR</strong>START detected<br />

the presence of an ABR operating system exit installed via SMP in the<br />

named module. The ABR operating system exits that are SMP installed<br />

must be removed if they are to be dynamically installed.<br />

16 UNABLE TO OBTAIN CMS LOCK – Call INNOVATION DATA PROCESSING.<br />

17 FREEMAIN ERROR – Call INNOVATION DATA PROCESSING.<br />

18 UNABLE TO OBTAIN LOCAL LOCK – Call INNOVATION DATA<br />

PROCESSING.<br />

19 modname CDE NOT FOUND – Call INNOVATION DATA PROCESSING.<br />

20 {ENQUEUE/DEQUEUE} ERROR ON IAM RESOURCE –<br />

21 {ENQUEUE/DEQUEUE} ERROR ON SYSZSVC – Call INNOVATION<br />

DATA PROCESSING.<br />

22 INVALID VECTOR TABLE STATUS – Call INNOVATION DATA PROCESSING.<br />

23 INVALID VECTOR TABLE CDE ADDRESS – Call INNOVATION DATA<br />

PROCESSING.<br />

24 RC= xxxx FROM SVCUPDTE – Call INNOVATION DATA PROCESSING.<br />

25 NO MODULES TO INSTALL - <strong>FDR</strong>OPT – The dynamic installation options<br />

that indicate which of the ABR operating system exits are to be installed<br />

specified that none of the exits is to be installed. These options (ABRLOC,<br />

ABRDSNF, ABRPRE, and IEBCOPY) are set in the <strong>FDR</strong> Global Options Table,<br />

module <strong>FDR</strong>OPT, using the ABR Install dialog (ISPF panel A.I.4.11.1).<br />

26 <strong>FDR</strong> SYSTEM MODULES INSTALL CANCELLED – This message is<br />

displayed when the console operator replies “NO” to the <strong>FDR</strong>W47 message.<br />

27 modname AND IAMVECTB ARE OUT OF SYNCH –<br />

28 VECTOR TABLE CANNOT BE STOPPED –<br />

29 <strong>FDR</strong>OPT MODULE LEVEL IS NOT HIGH ENOUGH – The dynamic<br />

installation options are not present in the level of <strong>FDR</strong>OPT that was loaded.<br />

30 PARM (PROD OR TEST) NOT SPECIFIED –<br />

31 HIGHER LEVEL OF VIF ALREADY ACTIVE –<br />

32 modname ERROR – Call INNOVATION DATA PROCESSING.<br />

33 modname ERROR – Call INNOVATION DATA PROCESSING.<br />

34 SYSEVENT DONTSWAP ERROR – Call INNOVATION DATA PROCESSING.<br />

35 PROGRAM LEVEL LOWER THAN VECTOR TABLE – Call INNOVATION<br />

DATA PROCESSING.<br />

36 VECTOR TABLE TO BE REPLACED NOT FOUND – Call INNOVATION<br />

DATA PROCESSING.<br />

37 TBL LEVEL NOT HIGH ENOUGH FOR REPLACE – Call INNOVATION<br />

DATA PROCESSING.<br />

38 modname - CSVDYLPA RC=xxxx-xxxxxxxx – Call INNOVATION DATA<br />

PROCESSING.<br />

39 modname NOT FOUND – Call INNOVATION DATA PROCESSING.<br />

40 modname {ENQUEUE/DEQUEUE} ERROR ON SYSZCSV/CSVDYLPA –<br />

Call INNOVATION DATA PROCESSING.<br />

41 modname INSTALLING <strong>FDR</strong>019VM – Call INNOVATION DATA<br />

PROCESSING.<br />

42 modname - CSVDYNEX RC=xxxx-xxxxxxxx – Call INNOVATION DATA<br />

PROCESSING.<br />

If error cannot be determined, contact INNOVATION DATA PROCESSING for assistance.<br />