FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
FDR V54L78 - Innovation Data Processing
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MESSAGES AND CODES<br />
MESSAGES FROM <strong>FDR</strong>, DSF, AND ABR (<strong>FDR</strong>NNN) 100.3<br />
<strong>FDR</strong>412 NO ABRINIT, MAINT, OR SELECT CONTROL STATEMENTS – VTOC UPDATE<br />
PROCESSING NOT REQUIRED<br />
Reason: No ABRINIT, MAINT, or SELECT control statements were read during processing of the SYSIN.<br />
Action:<br />
If the assumption was correct, none. Otherwise, you should add the correct control statements.<br />
<strong>FDR</strong>413 DSN/DSG type ERROR -- description<br />
Reason: There is an error in the specification of the DSN= or DSG= operand. “description” may be:<br />
Action:<br />
MAX INDEX LEVEL EXCEEDED – A maximum of 22 leading periods are allowed.<br />
NO SIGNIFICANT DATA – The leading periods were followed by a comma or blank.<br />
INVALID CHARACTERS – Invalid characters in the name.<br />
INVALID GENERATION – A GDG generation number was specified, but it is invalid.<br />
MAX INDEX LENGTH EXCEEDED – An index level exceeded 8 characters.<br />
Refer to the documentation in this manual for the program you are executing. Correct<br />
and resubmit.<br />
<strong>FDR</strong>414 IGNORED -- description -- DSN=dsname<br />
Reason: The device type returned for the data set was not that of a disk device or the data resides on<br />
multiple volumes. The processing requested for this data set is not performed.<br />
Action: Correct and resubmit job.<br />
<strong>FDR</strong>415<br />
Reason:<br />
Action:<br />
ON VOLSER vvvvvv(uuuu) - DSCB tt-cccchhhhrr-CHAINED TO DSCB tt-cccchhhhrr - action<br />
An invalid DSCB chain was detected in the VTOC of volume “vvvvvv” and the unit<br />
“uuuu” on which the volume resides. Information is displayed for the current DSCB<br />
and the invalid DSCB it chains to. “tt” is the DSCB type (1-7) and “cccchhhhrr” is the<br />
record address (cylinder, track, and record number) of the DSCB. “action” may be:<br />
PROCESSING CONTINUES – If the information in the DSCB is not critical for this<br />
operation.<br />
NOT FOUND IN INCORE VTOC – If the chained DSCB is not found in a copy of the<br />
VTOC saved in storage. The operation is terminated.<br />
NOTE: “uuuu” displays as “0000” when the DATATYPE is TVTOC.<br />
Even though the program may have been able to continue, this is a serious problem.<br />
Determine the data set(s) involved and attempt to correct the DSCB. You can use<br />
COMPAKTOR to help confirm and identify the error. If unable to determine the cause<br />
of the error, contact INNOVATION DATA PROCESSING for assistance.<br />
<strong>FDR</strong>416 IMPROPER USE OF OPERAND -- description<br />
Reason: An operand was used improperly. “description” identifies the operand and the reason.<br />
Action: Refer to the documentation in this manual for the program you are executing. Eliminate<br />
the bad operand or use it correctly.<br />
<strong>FDR</strong>417 USE OF RESTRICTED FEATURE -- description<br />
Reason: A feature has been disabled in the <strong>FDR</strong> Global Options Table. “description” identifies<br />
the feature. Attempts to use a disabled feature results in the sub-command being<br />
marked in error.<br />
Action: Eliminate the restricted feature. Rerun or restart the job.<br />
<strong>FDR</strong>418 COMMAND PROCESSING DETECTED ERROR--action<br />
Reason: An error was encountered during the processing of a statement. Always proceeded by<br />
one or more messages that define the error. “action” is one of:<br />
RE-ENTER COMMAND OR END – Message for user that has SYSIN data set<br />
assigned to a TSO terminal. Re-enter command in error or “END” to<br />
complete the processing.<br />
SKIPPING FOR COMMAND – <strong>Processing</strong> continues for all command statements<br />
found within the SYSIN data set.<br />
CHAPTER 100 – PAGE 100-82 –