Chapter 5 <br />

• Audio quality rate >95%<br />

Precautions:<br />

Clearly specify the zones of this type, avoid the common parts, rest rooms, stairs,<br />

elevators and room angles/extremities. (Take into account the field level recommendations<br />

relative to Full DECT).<br />

3. Level 3<br />

The coverage is good but some areas are probably in a shadow zone. Therefore cut-offs<br />

and interference are to be expected.<br />

The recommended commitment values for this level are:<br />

• Call establishment success rate >90%<br />

• Audio quality rate >85%<br />

Precautions:<br />

Clearly specify the zones of this type, taking into account the recommendations for field<br />

level relative to DECT.<br />

4. Level 4<br />

The coverage is not guaranteed.<br />

Work-around solutions are offered according to the customer's needs (case of rarely<br />

frequented zones where the accessibility can be obtained by installing one-off solutions).<br />

In the case where the customer has demands that exceed our own assessment, then<br />

depending on the commercial context, we must:<br />

• Either sell a pre-study that is more comprehensive, to better specify the<br />

Alcatel-Lucent Enterprise level of commitment<br />

• Or present two offers specifying the hypotheses version:<br />

i. What Alcatel-Lucent Enterprise feels is sufficient<br />

ii. What would be required to meet the customer's demands<br />

When a results commitment is requested, we must:<br />

• Avoid fixing the resources (number of base stations, etc.) as a more in-depth study<br />

may enable us to reduce the number of base stations and, as a result, increase our<br />

global margin<br />

• Increase the assessment to cover the risk relative to the number of base stations<br />

(5% if the requirements expression data are accurate and more in the case of<br />

uncertainties)<br />

Caution:<br />

In all cases, do not make a results commitment for a site that has not been visited.<br />

General Rules<br />

Traffic Calculation Rules<br />

Even though, in most cases today, the number of base stations is linked more to coverage<br />

rather than traffic objectives, it is a good idea to make sure of the suitability of the customer's<br />

capacity, in particular in the Full DECT case.<br />

The calculations must be carried out zone by zone.<br />

Reminder:<br />

A zone is a space that is homogeneous regarding difficulty of coverage, traffic and the required quality<br />

level<br />

To calculate the number of possible close base stations (or terminals) as well as the traffic<br />

when there is a reduction in the number of frequencies, refer to the document IBS NG : Rules<br />

5-16