In practice, you have to select this function (preferably the averaged measurement), set up a<br />

call, and observe the index value (Q): at a given location, the quality can be considered good if<br />

the value displayed is equal to or greater than 12 on a stable basis.<br />

CONNECTION STATUS (synchronization)<br />

This feature makes it easier to determine the coverage area of a base station.<br />

5.1.7 Reflexes DECT Sets<br />

5.1.7.1 Installing a set<br />

5.1.7.1.1 Installation procedure<br />

The registration of a DECT Reflexes set (with the 4097 CBL option) is performed by radio data<br />

exchange with the system. Before attempting the association, it is therefore important to check<br />

that the DECT bases are operational and that the sets are located in an area with adequate<br />

coverage.<br />

In order to limit traffic during installation of the sets, it is advisable to register the DECT<br />

Reflexes sets in sequence, one after the other.<br />

Note:<br />

The DECT-GAP authentication procedure (described in file 3) is not available with DECT<br />

Reflexes sets.<br />

REGISTRATION PROCEDURE FOR A NEW SET<br />

New sets are delivered from the factory without any registration data; they are brought into<br />

service using a simplified procedure.<br />

After adding a DECT set, go into GAP registration (MMC-Station or MMC-OMC) and initialize<br />

the association procedure up to "Subscription running".<br />

Then switch on the set's power supply, connecting the transformer block to the power outlet<br />

and check the red LED at the back of the set: the LED should send a short series of "long<br />

ON/short OFF" flashes, then go out as soon as the set is synchronized with a base station.<br />

At this point, the registration request is performed automatically by the set. The terminal<br />

identifier appears on the system's MMC and the attendant only needs to validate the directory<br />

number and confirm the registration.<br />

Note: after the registration phase, if the directory number of a DECT Reflexes set has to be<br />

changed, its power supply block must be disconnected, then reconnected, after the<br />

modification has been made in the system.<br />