MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](10) Two-Way Radio SystemProvide two-way radio systems as required. System(s) shall be as manufactured by Motorola,Johnson, Vertex Standard, or approved equivalent, as updated to most current technology ormanufacturer.(11) Video Teleconferencing System (VTS)Provide VTS systems as required. System(s) shall be as manufactured by Polycom,Tandberg, HP, or approved equivalent, as updated to most current technology ormanufacturer.(12) Satellite SystemProvide VTS systems as required. System(s) shall be as manufactured by Scientific Atlanta,Blonder Tongue, Pico Macom, or approved equivalent, as updated to most current technologyor manufacturer.6.8.2 TELECOMMUNICATIONS/SPECIAL SYSTEMS ROOMS AND SPACE REQUIREMENTSA. ScopeThis chapter covers the requirements for telecommunications, data, and special systemsrooms and spaces.B. Room Types and Definitions(1) GeneralProvide rooms as determined by project requirements. Not all room types may be required,and not all required room types may be listed below.(2) //Telephone Console Room (TCR) (Optional)The Telephone Console Room is where telephone operators are located. Operators provideservice to the entire building. The Telephone Console Room is in many cases, but not all,continuously staffed. At many locations the operators also have the responsibility <strong>of</strong>monitoring critical alarms for equipment throughout the facility.//(3) //Head End Equipment (HE) Room (Optional)The Head End (HE) Equipment Room will be located in the general mechanical penthouse orother area dictated by system design. The room will accommodate all provided and plannedSpecial Systems, Head-end Cabinets (i.e., MATV, SSTV, SSTV, RED, Satellite TV, PA, Two-Way Radio, Radio Paging, and M/W Radio, etc.). The room will be sized for a minimum <strong>of</strong> (5)each separate systems.//(4) Telecommunications Room (TR)The Telecommunications Room is a room designed to centrally deliver data, telephone, andspecial systems services to users and equipment on that floor. There may be multiple roomson a floor.The design "Telecommunications Room" replaces the term "Signal Closet," which is no longerused. The new designation indicates the current construction practice <strong>of</strong> combiningtelephone, data, special systems, and fire alarm functions into one terminus, control, anddistribution point. If security requirements require separation <strong>of</strong> systems, this will beaccomplished by a chain link or other barrier that will provide physical security while allowingcommon lighting, heating and cooling, and power protection systems.Part I: Basic Solicitation Requirements – Page 132 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!