12.07.2015 Views

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]tamper-pro<strong>of</strong>. Expansion shields shall be fiber, lead, or rubber as recommended by accessorymanufacturer for component and substrate.Stainless steel shall have No. 4 satin brushed finish, unless otherwise noted. Chrome/NickelPlating shall conform to ASTM B456, Type SC 2, satin finish, unless otherwise noted.Galvanizing for items other than sheet metal shall conform to ASTM A123, 1.25oz/sq yd.7.15 WINDOW TREATMENTSAll exterior windows shall be equipped with window blinds or shades.7.15.1 WINDOW BLINDSBlinds may be aluminum or plastic vertical blinds, or horizontal blinds with aluminum slats <strong>of</strong>one inch width or less. The window blinds must have non-corroding mechanisms andsynthetic tapes.7.15.2 CLOTH WINDOW SHADESProvide opaque cloth shades on windows <strong>of</strong> //radiographic and fluoroscopic rooms, // specialprocedures rooms, //cardiac catheterization rooms, // eye-clinic rooms, // exterior conferencerooms, and rooms containing image intensifiers.7.16 //HOLDING ROOM//Construct walls for holding room from minimum 4-inch [101.6-mm] CMU or 7/8-inch [24.76-mm] PCP (Portland Cement plaster on high-rib lath). Design wall studs for plaster partitionsfor maximum deflection <strong>of</strong> 1/120 <strong>of</strong> the wall height. Studs shall be minimum 4-inch 0.059", 16-gauge. Ceiling shall be 5/8-inch [15.88 mm] GWB.////Construct walls for holding room with 5/8-inch [15.88 mm] abuse-resistant GWB over securitymesh on metal studs as specified for plaster finish. Metal lath or plaster base is unacceptableas security mesh. Security mesh shall be flattened, expanded metal manufactured from highstrength, low alloy steel and shall conform to ASTM F 1267, Type 11, Class 1, Mill finish. Mesh designation: 3/4 #13F Mesh Design Size: 0.923 x 2.10 inch Mesh Opening Size: 0.688 x 1.781 inch 13 meshes per foot, 74% open area Mesh Strand Width: 0.106 inch Mesh Strand Thickness: 0.078 inch Weight: 0.75 pounds per square footProvide manufacturer’s attachment clips and use recommended fasteners to secure mesh towall framing.//The Holding Room should be contiguous with Security Operations Room and contain ashatterpro<strong>of</strong> observation window in the door. The door shall open outward. The holding roomshall not have exterior windows.Part I: Basic Solicitation Requirements – Page 174 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!