MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY](2) ConfigurationThe Entrance Room shall be a minimum <strong>of</strong> 12 feet x 8 feet[3.7 m x 2.4 m], and shall beequipped with backboards as required by system design.(3) Other RequirementsAll other requirements <strong>of</strong> Paragraph 6.8.2C General Environmental, Power and SpaceRequirements apply to the Entrance Room.J. Telephone Equipment Room (TER)(1) LocationThe TER shall be located within a cable distance <strong>of</strong> 100 feet [30 m] <strong>of</strong> the Telephone ConsoleRoom (if provided). It should be located close to the DEMARC and MCR rooms (if provided).A floor drain, evacuating and/or sump water pump, etc., shall be provided within the room ifrisk <strong>of</strong> water ingress exists. A high water level alarm annunciating system shall be provided inaddition to intrusion alarm(s) that connects to the facility’s ECR, PCR, SMS Console, and oneother continuously-manned location.(2) ConfigurationSpace shall be per the following table:Minimum Telephone Equipment Room SizeNUMBER OF LINES ROOM SIZE SQ FT [SQ M](GEN SIZE)200 to 300 168 [11] (12’ X 14’)301 to 600 250 [23.5] (12’ X 20’)601 to 900 500 [47] (20’ X 25’)901 to 1,600 700 [65] (20’ X 35’)1,601 to 2,000 900 [84] (20’ X 45’)2,001 to 2,400 1,100 [102] (20’ X 55’)2,401 to 2,800 1,300 [121] (25’ X 44’)2,801 to 3,200 1,500 [140] (34’ X 45’)3,201 to 4,000 1,700 [158] (34’ X 50’)A minimum <strong>of</strong> 3 feet [910 mm] shall be provided around each cabinet unless the cabinets areinstalled joined or side by side where the 3-foot [910-mm] rule applies around the entireassembly. Minimum suspended ceiling height shall be 8 feet [2.4 m] above finish floor. TheTER shall be a minimum <strong>of</strong> 12 feet x 14 feet [3.7 m x 4.3 m].Provide a metal insulated door equipped with a deadbolt key lock and/or electronic lock. Also,each door shall be provided with an intrusion alarm to be annunciated locally, at the Facility’sEngineering Control Room, Security Police Control Console, and one other continuouslymannedlocation (i.e., Telephone Operator or MAS Emergency Room Desk).Sufficient backboards shall be provided to limit interconnection wire and cable length frombackboard to the room wire management system and planned cabinets. Backboards shall belocated so as to allow unobstructed access to entrance and exit cable ducts, internal roomwire management system, cabinets and doors.Part I: Basic Solicitation Requirements – Page 140 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!