MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]VA Accessibility Standards from PG-18-13ParagraphDescription <strong>of</strong> Requirement3’-6" x 6’-0" minimum size "front transfer" stallGrab bars are required in all stalls (not just accessible stalls)4.22 3’-0" (36") minimum width <strong>of</strong> toilet room entrance doors5.0 Cafeterias:2’-3" (25") minimum knee clearance dimension, and2’-5" (27") for minimum 5-percent <strong>of</strong> tables40 to 48" range for cutlery and supply height4.7 OSHA REQUIREMENTSThe Lessor agrees to comply with all Occupational Safety & Health Administration (OSHA)Safety and Health Standards located in 29 CFR.4.8 SUSTAINABLE DESIGN AND ENERGY EFFICIENCY4.8.1 LEED® SILVER EQUIVALENCYDemonstrable LEED® Silver equivalency is required. Lessor shall provide documentation thatthe design and construction <strong>of</strong> facilities meets this goal. From the entirety <strong>of</strong> available LEED®Credits, certain credits are mandatory. The Lessor shall supplement the mandatory creditswith other credits chosen to accomplish sufficient credits for LEED® Silver equivalency. Thelatest version <strong>of</strong> LEED® available shall be used. The mandatory credits (based on LEED® 3)are:Water Efficiency: Credit 1 Water Efficient Landscaping, Reduce By 50%Energy & Atmosphere: Credit 3 Enhanced CommissioningMaterials and Resources: Credit 5 Regional Materials, 20% <strong>of</strong> MaterialsIndoor Environmental Quality: Credit 2 Increased VentilationIndoor Environmental Quality: Credit 3.2 <strong>Construction</strong> IAQ <strong>Management</strong> Plan – BeforeOccupancyInnovation & Design:Credit 2 LEED Accredited Pr<strong>of</strong>essionalLEED® prerequisites necessary to obtain the required credits are also required. Theseinclude:Water EfficiencyEnergy & Atmosphere:Materials and Resources:Indoor Environmental Quality:WEp1, Water Use ReductionEAp1, Fundamental Commissioning <strong>of</strong> Building EnergySystems; EAp2, Minimum Energy Performance; and PR3,Fundamental Refrigerant <strong>Management</strong>MRp1, Storage and Collection <strong>of</strong> RecyclablesEQp1, Minimum Indoor Air Quality Performance; EQp2,Environmental Tobacco Smoke (ETS) ControlPart I: Basic Solicitation Requirements – Page 73 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!