12.07.2015 Views

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SOLICITATION FOR OFFERS OUTPATIENT CLINIC[INSERT LOCATION OF FACILITY]MAY 2009<strong>SFO</strong> No. VA-101-XX-RP-XXXXWainscotHardwareDepartment / Functional Area RoomCode Qty FunctionElectro-Encephalography Laboratory (EEG)SCHEDULE E: ROOM FINISH, DOOR, AND HARDWARE SCHEDULEUnitArea sf(eachroom)Net AreasfExcludefrom NetUsable Floor Base WallEEG OPEE1 2 EEG Exam Room 120 240 VCT RB GWB-P - AT 9'-0" 1 / 2 V-M 25EEG OPEE2 1 EEG Instrument and Work Room 205 205 VCT RB GWB-P - AT 9'-0" 1 / 2 U-T 67EEG OFA02 2 <strong>Office</strong>, Technician 100 200 VCT RB GWB-P - AT 9'-0" 1 / 2 S-T 67EEG MRS01 1 Storage, EEG Records 150 150 VCT RB GWB-P - AT 9'-0" 1 / 2 U-T 13CeilingCeilingHeightDoorSymbolNotesDigestive Diseases Program--EndoscopyEndoscopy DR001 4 Changing Area, Patient 60 240 VCT RB GWB-P - AT 9'-0" 1 / 2 S 18Endoscopy RROP1 2 Cubicle, Patient Recovery 100 200 VCT RB GWB-P - AT 9'-0" 1 / 2 W 67Endoscopy XVC01 1 Dictation / Viewing Room 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23GWB Lay-InRSF RSF GWB-SC -Endoscopy TREE1 2 EGD Procedure Room 300 600Panels9'-0" 1 / 2 V 69Endoscopy JANC1 1 Housekeeping Aides Closet (HAC) 40 40 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13Endoscopy NSTA4 1 Nurse Station 100 100 VCT RB GWB-W - AT 9'-0" Open -Endoscopy 0FD03 1 <strong>Office</strong>, GI Assistant 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23Endoscopy RECP1 1 Reception Area 120 120 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23Endoscopy USCL2 1 Scopes Clean-up, Sterilization and Storage Room 120 120 WSF WSF GWB-SC - AT (SP) 9'-0" 1 / 2 S 23Endoscopy RCA01 1 Storage, Crash Cart 20 20 VCT RB GWB-P - AT 9'-0" Open -Endoscopy TLTU1 3 Toilet, Patient 50 150 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18Endoscopy UCCL1 1 Utility Room, Clean 100 100 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 45Endoscopy USCL1 1 Utility Room, Soiled 80 80 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42Endoscopy WRC01 1 Waiting Area 150 150 VCT / CP RB GWB-W - AT 9'-0" Open -EngineeringEngineering BMER1 1 Biomedical Engineering Repair Shop 200 200 VCT RB GWB-P - AT 9'-0" 1 / 2 SS-T 82Environmental <strong>Management</strong> (EMS)EMS JANC1 7 Housekeeping Aids Closet (HAC) 40 280 CT CT GWB-EPY CT 4'-0" AT (SP) 9'-0" 1 / 2 T 13 One per 13,000 nsf; distribute throughout OPCEMS SHRHM1 1 Infectious / Hazardous Waste 120 120 WSF WSF GWB-SC - GWB-SC 9'-0" 11 / 12 V-F 42EMS OFA02 1 <strong>Office</strong>, Chief 150 150 VCT / CP RB GWB-W - AT 9'-0" 1 / 2 S 23EMS SEC01 1 <strong>Office</strong>, Secretary and Waiting 120 120 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S 23EMS UTC01 1 Recyclable Waste 120 120 C-EPY RB GWB-P - EXP - 10 X 43EMS LCCL1 1 Storage, Clean Linen Cart 100 100VCT RB GWB-SC CT 5'-0" AT (SP) 9'-0" 11 / 12 SS-F 43EMS SRSE1 1 Storage, Environmental <strong>Management</strong> Supplies / Large Equipment 750 750 VCT RB GWB-P - AT 9'-0" 11 / 12 V-F 69EMS LCSL1 1 Storage, Soiled Linen Cart 100 100VCT RB GWB-SC CT 4'-0" AT (SP) 9'-0" 11 / 12 SS-F 43Eye ClinicEye Clinic TREY1 1 Exam / Treatment Room 130 130 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic EYFD1 1 Fitting and Dispensing Room 120 120 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic OFA02 1 <strong>Office</strong>, Blind Rehabilitation (VIST), Counselor 120 120 VCT / CP RB GWB-P/W - AT 9'-0" 1 / 2 V 23Eye Clinic OFD03 6 <strong>Office</strong>, Eye Care Provider 120 720 VCT / CP RB GWB-P/W - AT 9'-0" 1 / 2 V 23Eye Clinic EYVS1 1 Photography Room 150 150 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic RECP1 1 Reception Area - 0 VCT / CP RB GWB-P - AT 9'-0" 1 / 2 S-T 23Eye Clinic EYVF1 1 Visual Fields Room 130 130 VCT RB GWB-P/W - AT 9'-0" 1 / 2 V 25Eye Clinic WRC01 1 Waiting Area (Dilation) 60 60 VCT / CP RB GWB-W - AT 9'-0" Open -LobbyLobby OFA02 1 Escort Room 150 150 VCT RB GWB-P - AT 9'-0" 1 / 2 T 23Lobby RECP3 1 Information Desk 100 Finishes 100 to be selected on basis <strong>of</strong> requirements and costLobby LOB01 1 Public Telephones 30 Finishes 30 to be selected on basis <strong>of</strong> requirements and costLobby SRLW1 1 Storage, Wheelchair 100 100 VCT RB GWB-P - AT 9'-0"Lobby TLTU1 1 Toilet, Female, Public 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 14 Use HW Set 1 for Multi-use TolietsLobby TLTU1 1 Toilet, Male, Public 50 50 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 14 Use HW Set 1 for Multi-use TolietsLobby WRC01 1 Waiting Area 200 Finishes 200 to be selected on basis <strong>of</strong> requirements and costEMS: Lockers, Lounges, Toilets and Showers (LLTS)EMS: LLTS LR002 1 Locker Room 1,500 1,500 VCT RB GWB-P - AT 9'-0" 1 / 2 S 1EMS: LLTS TLTS1 1 Shower, Female Staff 50 50 CT CT GWB-EPY CT 4'-0" PCP-EPY 9'-0" 1 / 2 S 1 Full Height CT at Shower StallEMS: LLTS TLTS1 1 Shower, Male Staff 50 50 CT CT GWB-EPY CT 4'-0" PCP-EPY 9'-0" 1 / 2 S 1 Full Height CT at Shower StallEMS: LLTS TLTU1 10 Toilet, Staff 50 500 CT CT GWB-P CT 4'-0" AT 9'-0" 1 / 2 S 18______Lessor Gov't_______ Room Finish, Door and Hardware--Schedule E Page 26 <strong>of</strong> 31 ___ <strong>of</strong> _____ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!