MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]SECURITY REQUIREMENTS for SPECIAL AREASLOCATIONAPPLICABLE REQUIREMENTS (X)(See list below table)1 2 3 4 5 6 7 8 9 10 11 12 13 14Canteen Retail Store X O X X X X XCanteen Storage Room X O X X X X XCanteen <strong>Office</strong> X O X X X X O XAgent Cashier X X X X X X XPharmacy and Supply X X X X X X X X X XDrug Storage RoomsPharmacy Dispensing X X X X X XAreasPharmacy Manufacturing X X X X X X XAreaAcquisition & Materiel O X X X X X<strong>Management</strong> (A&MM)(Supply Warehouse)Dental Precious Metal O X O X XStorageInformation Resources X X X X X X<strong>Management</strong> – DHCPMain TelephoneX X X X X XEquipment Room;Computer RoomEmergency Room andTreatment RoomsX X X1: WindowsWindows with sills less than 40 feet [12.19 m] from the ground or the ro<strong>of</strong> <strong>of</strong> a lower abutment,less than 25 feet from windows <strong>of</strong> an adjoining building, and accessible by a building ledgeleading to windows <strong>of</strong> other floor rooms require security mesh screening. Stainless steelsecurity mesh screening shall be equivalent to woven mesh 0.028" wire diameter alloy #304stainless steel, and have a tensile strength <strong>of</strong> 800 pounds per lineal inch. Mesh shall beequivalent to 12 x 12 per inch with main and sub frames <strong>of</strong> 12 gauge carbon steel with bakedenamel finish and internal key locking slide bolts. Security mesh screens are to be installedon inside <strong>of</strong> windows.2: WallsAll walls or partitions for the designated room shall be constructed to resist forced entry.Exterior walls <strong>of</strong> brick or masonry construction shall be acceptable. Metal stud walls shall bereinforced with security mesh to provide equivalent protection.Interior partitions may be solid 4-inch CMU or metal stud with security mesh.Metal lath or plaster base is unacceptable as security mesh. Security mesh shall be flattened,expanded metal manufactured from high strength, low alloy steel and shall conform to ASTMF 1267, Type 11, Class 1, Mill finish. Mesh designation: 3/4 #13F; Mesh Design Size 0.923 x2.10 inch; Mesh Opening Size 0.688 x 1.781 inch; 13 meshes per foot, 74% open area; MeshStrand Width 0.106 inch; Mesh Strand Thickness 0.078 inch; Weight 0.75 pounds per squarePart I: Basic Solicitation Requirements – Page 62 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!