12.07.2015 Views

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Gypsum Wallboard epoxy coating, (SC):1 coat primer sealer2 coats waterborne epoxy //semi-gloss// //gloss//Ferrous and Galvanized Metal:1 coat vinyl acrylic primer or vinyl pre-wash primer (if not factory-primed)2 coats acrylic latex enamel //low luster// //semi-gloss// //gloss//Wood – Transparent Finish:Provide hand-wiped stained finish, water-based, clear acrylic, premium grade //glossand color as selected// //[specify gloss and color//Stain2 coats clear finish7.11 HANDRAILS, WALL GUARDS AND CORNER GUARDSAn estimate <strong>of</strong> base quantities <strong>of</strong> each type <strong>of</strong> handrail, wall guard, and corner guard thatshould be included in the proposed rental rate is indicated in Schedule C. Adjustments will bemade at the end <strong>of</strong> the project based on actual measurement and payment will be made perthe pre-negotiated unit cost for these items.Stainless steel shall conform to ASTM A167, Type 302B. Extruded aluminum componentsshall conform to ASTM B221, Alloy 6063, Temper T5 or T6. Resilient materials shall beextruded and injection molded acrylic vinyl or extruded polyvinyl chloride meeting followingrequirements:Minimum impact resistance <strong>of</strong> 2150 ft-lbs [200 Nm] (when tested in accordance withASTM D256 (Izod impact, ft-lbs per inch notch).Class 1 fire rating when tested in accordance with ASTM E84, having a maximumflame spread <strong>of</strong> 25 and a smoke developed rating <strong>of</strong> 450 or less.shall be rated self extinguishing when tested in accordance with ASTM D635Material shall be labeled and tested by Underwriters Laboratories or other approvedindependent testing laboratory.Provide resilient materials with integral color with all colored components matched inaccordance with SAE J 1545 to within plus or minus 1.0 on the CIE LCH scales.7.11.1 HANDRAILS AND WALL GUARDSExcept in administrative areas, provide handrails and wall guards on both sides <strong>of</strong> allcorridors. Provide chair rail at locations indicated in Schedule C. Provide continuousreinforcing in the wall attachment <strong>of</strong> handrails and bumper guards.Handrail/Wall Guard Combination shall consist <strong>of</strong> snap-on covers <strong>of</strong> resilient material,minimum 0.078-inch thick, free-floated on a continuous, extruded aluminum retainer, minimum0.072-inch thick, anchored to wall at maximum 32 inches on center.Part I: Basic Solicitation Requirements – Page 167 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!