12.07.2015 Views

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Do not use toilet stalls or divider partitions in single-user toilet rooms in which only a lavatoryand water closet are provided.Conform to Fed. CID A-A-60003, except as modified herein. Fabricate to dimensions shownor specified.Toilet Enclosures shall be Type 1, Style B (Ceiling hung) // C (overhead braced) //. Reinforcepanels to receive toilet tissue holders, grab bars, or other accessories specified. Upper pivotsand lower hinges shall be adjustable to hold doors open 30 degrees. Latching devices andhinges for handicap compartments shall comply with accessibility requirements.Finish: //Baked enamel on steel doors, pilasters, and enclosure panels, except those adjacentto urinals, which shall be stainless steel// //Solid phenolic or solid polyethylene //: waterresistant, graffiti resistant, non-absorbent, contain a minimum 30% post consumer recycledplastic, Class C flame spread rating.//Urinal Screens shall be Type III, Style D (wall hung), //stainless steel// //solid phenolic// //solidpolyethylene//, with integral flanges and continuous, full height wall anchor plate. Screensshall be 24 in' wide x 42 in high [600 mm wide x 1070 mm high].7.14.2 SHOWERSUse ceramic tile applied with thinset Portland cement to concrete-fiber reinforced backer boardfor shower enclosures and partitions <strong>of</strong> contiguous areas. Warp finished floors <strong>of</strong> adjoiningdrying rooms or toilet rooms toward showers to assure drainage to the shower drain. Floorslopes in and around a shower shall not exceed 5%.Construct all patient showers without curbs. In non-patient shower rooms, provide at least oneshower stall without a curb.7.14.3 TOILET AND SHOWER ACCESSORIESTypes and locations <strong>of</strong> toilet accessories shall be as indicated in Schedule B <strong>of</strong> thissolicitation. Multiple units <strong>of</strong> each type <strong>of</strong> accessory shall be furnished by the samemanufacturer. Lessor shall provide suitable backing and other preparation as necessary foritems indicated to be furnished by VA.Toilet accessories shall be shop or factory assembled, free <strong>of</strong> dents and scratches andpackaged complete with anchors and fittings, steel anchor plates, adapters, and anchorcomponents for installation. Grind welded joints smooth. Fabricate units made <strong>of</strong> metal sheet<strong>of</strong> seamless sheets with flat surfaces.Stainless steel sheet shall conform to ASTM A167, Type 304. Stainless steel tubing shallconform to ASTM A269. Galvanized sheet steel shall conform to ASTM A653, G60.Mirror glass shall be float glass, Type I, Class 1, Quality q2 (ASTM C 1036), with silvering,copper coating, and suitable protective organic coating to copper backing in accordance withFS DD-M-411.Adhesive shall be two component epoxy type or contact type and waterpro<strong>of</strong>. Fasteners,screws, and bolts shall be stainless steel or hot dip galvanized. Exposed fasteners shall bePart I: Basic Solicitation Requirements – Page 173 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!