12.07.2015 Views

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SFO Template - Office of Construction & Facilities Management Home

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]Intrusion detector equipment which operates on the principle <strong>of</strong> narrow beam interception,microwave, or photo electric eye is unacceptable.Installation Notes:A locally sounding alarm should not be installed in a room which is close to a cardiac care orother special treatment area where a loud alarm would have an injurious effect on patients.Intrusion detector alarms will be remotely monitored by a commercial security alarmmonitoring firm, a local police department, or a security <strong>of</strong>fice charged with building security.The remoted alarms will be in addition to locally broadcast alarms in the protected areas.6: Pharmacy Dispensing CounterPartitions and windows <strong>of</strong> pharmacy dispensing counters shall be UL Level 3 ballisticconstruction and 15-minute forced entry construction, including partitions, doors, glazedopenings, teller windows, and transaction trays.7: Agent Cashier CounterPartitions and teller windows facing the public corridor shall be UL Level 3 ballisticconstruction and 15-minute forced entry construction, including partitions, doors, glazedopenings, teller windows, and transaction trays.8: Bulk Drug Storage Safes And VaultsDrugs classified as Schedule I or II controlled substances under the Controlled Substance Act<strong>of</strong> l970 must be stored in safes or vaults which conform to the following specifications://Safes will be GSA class 5 security containers weighing no less than 750 pounds. Dueconsideration shall be applied to the design <strong>of</strong> the floor system's live load capacity.////Lessor shall construct Type I vault for outpatient clinic. Size and location are shown on theconceptual layout in this <strong>SFO</strong>. Vault specifications are as follows:Type I Vault: Enclosures constructed on steel security screen, woven mesh, .047" wirediameter alloy #304 stainless steel, and have a tensile strength <strong>of</strong> 1,600 pounds per linealinch. Mesh 10 x 10 per inch with main frame and subframes <strong>of</strong> 13 gauge alloy #304 stainlesssteel. In rooms with dropped ceilings, the vertical frames and mesh walls must meet theactual ceiling or a security mesh ceiling installed below the false ceiling.//9: Bulk Drug Storage CabinetsSteel cabinet with adjustable shelving and built in locking devices are required for the storage<strong>of</strong> bulk supplies <strong>of</strong> Schedule II to V controlled substances.10: Security Surveillance TVSecurity surveillance TV camera with motion detector feature on cameras and at monitorlocation.11: Special Key ControlRoom door lock keys and day lock combinations, where applicable, are Special Keys and arenot mastered.Part I: Basic Solicitation Requirements – Page 64 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!