MAY 2009SOLICITATION FOR OFFERS OUTPATIENT CLINIC <strong>SFO</strong> NO. VA-101-XX-RP-XXXX[INSERT LOCATION OF FACILITY]//Interior Stairway Doors: Provide interior stairway doors with passage latch sets havinginside and outside door handles free at all times. Exceptions are where stairway doors arerequired to be locked to prevent entrance into and elopement from functional departments orareas. Locking shall comply with NFPA 101.//7.3.2 WOOD DOORSInterior wood doors shall be solid core, 1-3/4 inch thick, with [insert grade and species <strong>of</strong>veneers] face veneers for //transparent// //opaque paint// finish.Wood doors shall comply with Window and Door Manufacturer’s Association (WDMA) I.S.1-A,Heavy Duty with Type II adhesives.7.3.3 HOLLOW METAL DOORSHollow metal doors shall be 1-3/4 inch thick and comply with Standard Duty Doors per SteelDoor Institute (SDI) A250.8, Level 1, Model 2; except: Stairwell doors shall comply with Heavy Duty Doors: SDI A250.8, Level 2, Model 2.Security doors (Type 36) shall comply with Extra Heavy Duty Doors SDI A250.8, Level3, Model 2.Detention Doors (Type 22) shall comply with Extra Heavy Duty Doors SDI A250.8,Level 3, Model 2 with core type ‘d’ or ‘f.’7.3.4 HOLLOW METAL DOOR FRAMESA. Frames for Hollow Metal DoorsHollow metal door frames shall comply with Steel Door Institute (SDI) 250 for type and grade<strong>of</strong> doors required (Standard, Heavy Duty, or Extra Heavy Duty) and as follows. Frames shallbe welded construction; knockdown frames are not allowed. Frames for doors specified tohave automatic operators shall be minimum 16-gauge.B. Frames for Wood Doors//Hollow metal door frames shall be shop fabricated, pre-finished, site assembled steel frames.Provide fire rated assemblies where scheduled. Fabricate frames from cold rolled steel ASTMA1008, minimum 18-gauge; casings and trim minimum 20-gauge. Prepare frames for doorhardware. Provide reinforcements for hardware specified.Shop fabricated, pre-finished frames shall not be used for sound rated doors. Provide framescomplying with SDI 114.Shop fabricated, pre-finished frames shall not be used at openings scheduled to receivemortise locksets. Provide frames complying with SDI 250.////Hollow metal door frames shall comply with Steel Door Institute (SDI) 250 for Standard Duty,minimum 18 gauge.//Frames for wood doors specified to have automatic operators shall comply with Steel DoorInstitute (SDI) 250; shall be welded construction; knockdown frames are not allowed; and shallbe minimum 16 gauge.Part I: Basic Solicitation Requirements – Page 152 <strong>of</strong> 196Lessor __________ Gov’t. ____________________ <strong>of</strong> __________ Pages

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!