12.07.2015 Views

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Causes and corrective actionsOperation PanelIndicationNameDescriptionCheck pointCorrective actionOperation PanelIndicationNameDescriptionCheck pointCorrective actionOperation PanelIndicationNameDescriptionCheck pointCorrective action<strong>FR</strong>-PU04E.OPTOption Fault<strong>FR</strong>-PU07Option faultAppears when the AC power supply is connected to the terminal R/L1, S/L2, T/L3 accidentally when ahigh power factor converter is connected.· Check that the AC power supply is not connected to the terminal R/L1, S/L2, T/L3 when a high powerfactor converter (<strong>FR</strong>-HC, MT-HC) or power regeneration common converter (<strong>FR</strong>-CV) is connected.· Check the parameter (Pr. 30) setting and wiring.· The inverter may be damaged if the AC power supply is connected to the terminal R/L1, S/L2, T/L3when a high power factor converter is connected. Please contact your sales representative.· Return the switch for the manufacturer setting of the plug-in option to the initial status. (Refer toinstruction manual of each option)<strong>FR</strong>-PU04E.OP1Option 1 Fault<strong>FR</strong>-PU07Communication option fault<strong>Stop</strong>s the inverter output when a communication line error occurs in the communication option.· Check for a wrong option function setting and operation.· Check that the plug-in option is plugged into the connector securely.· Check for a brake in the communication cable.· Check that the terminating resistor is fitted properly.· Check the option function setting, etc.· Connect the plug-in option securely.· Check the connection of communication cable.<strong>FR</strong>-PU04E. 1Fault 1<strong>FR</strong>-PU07Option fault<strong>Stop</strong>s the inverter output if a contact fault or the like of the connector between the inverter andcommunication option occurs.Appears when the switch for the manufacturer setting of the plug-in option is changed.1. Check that the plug-in option is plugged into the connector securely.2. Check for excess electrical noises around the inverter.1. Connect the plug-in option securely.2. Take measures against noises if there are devices producing excess electrical noises around the inverter.If the problem still persists after taking the above measure, please contact your sales representativeor distributor.3. Return the switch position for the manufacturer setting of the plug-in option to the initial status. (Referto instruction manual of each option)Operation PanelIndicationNameDescriptionCheck pointCorrective action<strong>FR</strong>-PU04E.PECorrupt Memry<strong>FR</strong>-PU07Parameter storage device fault (control circuit board)Trips when a fault occurred in parameters stored (EEPROM failure)Check for too many number of parameter write times.Please contact your sales representative.When performing parameter write frequently for communication purposes, set "1" in Pr. 342 to enableRAM write. Note that powering off returns the inverter to the status before RAM write.Operation Panel<strong>FR</strong>-PU04 Fault 14E.PE2Indication<strong>FR</strong>-PU07 PR storage alarmNameParameter storage device fault (main circuit board)Description Trips when a fault occurred in parameters stored (EEPROM failure)Check point ——————Corrective action Please contact your sales representative.TROUBLESHOOTING5101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!