12.07.2015 Views

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Parameter listOperation selection at powerfailure and instantaneouspower failureOperation setting at faultoccurrenceEnergy saving operationReduction of the motor noiseMeasures against noise andleakage currentsFrequency setting by analoginputMisoperation prevention andparameter setting restrictionSelection of operation modeand operation locationCommunication operationand settingSpecial operation andfrequency controlUseful functionsSetting from the parameterunit and operation panelPurpose of UseRestart operation after instantaneous power failure/FlyingstartDecelerate the motor to a stop at instantaneous power failure Pr. 261 to Pr. 266Pr. 57, Pr. 58, Pr. 162 to Pr. 165, Pr.299, Pr. 611Retry function at fault occurrence Pr. 65, Pr. 67 to Pr. 69Output function of fault code Pr. 76Input/output phase loss protection selection Pr. 251, Pr. 872Regeneration avoidance function Pr. 882 to Pr. 886Energy saving control selection Pr. 60How much energy can be saved (energy saving monitor) Pr. 891 to Pr. 899Carrier frequency and SoftPWM selection Pr. 72, Pr. 240, Pr. 260Noise elimination at the analog input Pr. 74Analog input selection Pr. 73, Pr. 267Override function Pr. 73, Pr. 252, Pr. 253Noise elimination at the analog input Pr. 74Change of analog input frequency,adjustment of voltage, current input and frequency(calibration)Pr. 125, Pr. 126, Pr. 241,C2 to C7 (Pr. 902 to Pr. 905)Compensation at the analog input Pr. 242, Pr. 243Reset selection, disconnected PU detection Pr. 75Prevention of parameter rewrite Pr. 77Prevention of reverse rotation of the motor Pr. 78Display necessary parameters only. (user group) Pr. 160, Pr. 172 to Pr. 174Control of parameter write by communication Pr. 342Operation mode selection Pr. 79Operation mode when power is on Pr. 79, Pr. 340Operation command source and speed command sourceduring communication operationPr. 338, Pr. 339Selection of the NET mode operation control source Pr. 550Selection of the PU mode operation control source Pr. 551PU connector communicationPr. 117 to Pr. 124,Pr. 331 to Pr. 337, Pr. 341, Pr. 539Control of parameter write by communication Pr. 342ModbusRTU communication specifications Pr. 343Operation command source and speed command sourceduring communication operationPr. 338, Pr. 339Selection of the NET mode operation control source Pr. 550ModbusRTU protocol (communication protocol selection) Pr. 549PID control Pr. 127 to Pr. 134, Pr. 575 to Pr. 577Switch between the inverter operation and commercialpower-supply operation to usePr. 135 to Pr. 139, Pr. 159Free parameter Pr. 888, Pr. 889Increase cooling fan life Pr. 244To determine the maintenance time of parts. Pr. 255 to Pr. 259, Pr. 503, Pr. 504How much energy can be saved (energy saving monitor) Pr. 60, Pr. 891 to Pr. 899Parameter unit language switchover Pr. 145Operation selection of the operation panel Pr. 161Buzzer control of the operation panel Pr. 990Contrast adjustment of the parameter unit Pr. 991Parameter Number66

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!