Rating7 SPECIFICATIONS7.1 Rating•200V classType <strong>FR</strong>-F720-K 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110Applicable motor capacity(kW)*10.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110Rated capacity (kVA)*2 1.6 2.7 3.7 5.8 8.8 11.8 17.1 22.1 27 32 43 53 65 81 110 132 165OutputPower supplyRated current (A)*3Overload currentrating*4Voltage*5Rated input ACvoltage/frequencyPermissible ACvoltage fluctuationPermissible frequencyfluctuationPowersupplysystemcapacity(kVA)*6Without DCreactorWith DCreactorProtective structure(JEM 1030)*8Cooling system4.2(3.6)7.0(6.0)9.6(8.2)15.2(13)23(20)31(26)45(38)58(49)70(60)85(72)114(97)140(119)170(145)120% for 60s, 150% for 3s (inverse time characteristics)Three-phase 200 to 240VThree-phase 200 to 220V 50Hz, 200 to 240V 60Hz170 to 242V 50Hz, 170 to 264V 60Hz±5%212(180)288(245)346(294)2.1 4.0 4.8 8.0 11.5 16 20 27 32 41 52 65 79 99 - - -1.2 2.6 3.3 5.0 8.1 10 16 19 24 31 41 50 61 74 110 132 165SelfcoolingEnclosed type (IP20)*7Forced air coolingOpen type (IP00)Approx. mass (kg) 1.8 2.2 3.5 3.5 3.5 6.5 6.5 7.8 13 13 14 23 35 35 67 70 70*1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.*2 The rated output capacity indicated assumes that the output voltage is 220V.*3 When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverteroutput current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.*4 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeatedduty, allow time for the inverter and motor to return to or below the temperatures under 100% load.*5 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the settingrange. However, the pulse voltage value of the inverter output side voltage remains unchanged at about 2 that of the power supply.*6 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor andcables).*7 When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type ().*8 <strong>FR</strong>-DU07: IP40 (except for the PU connector)432(367)118

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!