12.07.2015 Views

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

List of faults or alarm display5.2 List of faults or alarm displayError messageWarningsMinor faultMajor faultOperation PanelIndicationtotoNameRefertoE--- Faults history 105HOLD Operation panel lock 93Er1 to 4 Parameter write error 93rE1 to 4 Copy operation error 93Err. Error 94OL Stall prevention (overcurrent) 95oL Stall prevention (overvoltage) 95RB Regenerative brake prealarm 96THElectronic thermal relayfunction prealarm96PS PU stop 95MT Maintenance signal output 96CP Parameter copy 96FN Fan fault 96E.OC1Overcurrent trip duringacceleration97E.OC2Overcurrent trip duringconstant speed97E.OC3Overcurrent trip duringdeceleration or stop97E.OV1Regenerative overvoltagetrip during acceleration97E.OV2Regenerative overvoltagetrip during constant speed98E.OV3Regenerative overvoltage tripduring deceleration or stop98E.THTInverter overload trip(electronic thermal relay function)98E.THMMotor overload trip(electronic thermal relay function)98E.FIN Fin overheat 99E.IPF Instantaneous power failure 99E.BEBrake transistor alarmdetection/internal circuit error99E.UVT Undervoltage 99E.ILF* Input phase loss 100E.OLT Stall prevention 100Major faultOperation PanelIndicationE.GF//Output side earth (ground)fault overcurrent100E.LF Output phase loss 100E.OHTExternal thermal relayoperation *2100E.PTC* PTC thermistor operation 100E.OPT Option fault 101E.OP1 Communication option fault 101E. 1 Option fault 101E.PEParameter storage devicefault101E.PUE PU disconnection 102E.RET Retry count excess 102E.PE2*Parameter storage devicefault101E. 6 /E. 7 /E.CPUNameCPU error 102E.CTEOperation panel powersupply short circuit, RS-485terminal power supply short102circuitE.P2424VDC power output shortcircuit102E.CDO*Output current detectionvalue exceeded103E.IOH*Inrush current limit circuitfault103E.SER*Communication fault(inverter)103E.AIE* Analog input fault 103E.13 Internal circuit fault 103Referto* If an error occurs when using the <strong>FR</strong>-PU04/<strong>FR</strong>-PU07, "Fault 14" isdisplayed on the <strong>FR</strong>-PU04/<strong>FR</strong>-PU07.92

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!