Peripheral devices2.1 Peripheral devicesCheck the inverter type of the inverter you purchased. Appropriate peripheral devices must be selected according tothe capacity. Refer to the following list and prepare appropriate peripheral devices:200V classMotorOutput (kW)*1Applicable Inverter TypeBreaker Selection*2,4Reactor connectionInput Side MagneticContactor*3Reactor connectionwithout withwith commercialpower-supplyoperation without with0.75 <strong>FR</strong>-F720-0.75K 30AF 10A 30AF 10A 30AF 10A S-N10 S-N101.5 <strong>FR</strong>-F720-1.5K 30AF 15A 30AF 15A 30AF 15A S-N10 S-N102.2 <strong>FR</strong>-F720-2.2K 30AF 20A 30AF 15A 30AF 20A S-N10 S-N103.7 <strong>FR</strong>-F720-3.7K 30AF 30A 30AF 30A 30AF 30A S-N20, N21 S-N105.5 <strong>FR</strong>-F720-5.5K 50AF 50A 50AF 40A 50AF 50A S-N25 S-N20, N217.5 <strong>FR</strong>-F720-7.5K 100AF 60A 50AF 50A 100AF 60A S-N25 S-N2511 <strong>FR</strong>-F720-11K 100AF 75A 100AF 75A 100AF 75A S-N35 S-N3515 <strong>FR</strong>-F720-15K 225AF 125A 100AF 100A 225AF 125A S-N50 S-N5018.5 <strong>FR</strong>-F720-18.5K 225AF 150A 225AF 125A 225AF 150A S-N65 S-N5022 <strong>FR</strong>-F720-22K 225AF 175A 225AF 150A 225AF 175A S-N80 S-N6530 <strong>FR</strong>-F720-30K 225AF 225A 225AF 175A 225AF 225A S-N95 S-N8037 <strong>FR</strong>-F720-37K 400AF 250A 225AF 225A 400AF 250A S-N150 S-N12545 <strong>FR</strong>-F720-45K 400AF 300A 400AF 300A 400AF 350A S-N180 S-N15055 <strong>FR</strong>-F720-55K 400AF 400A 400AF 350A 600AF 500A S-N220 S-N18075 <strong>FR</strong>-F720-75K ⎯ 400AF 400A 400AF 400A ⎯ S-N30090 <strong>FR</strong>-F720-90K ⎯ 400AF 400A 600AF 500A ⎯ S-N300110 <strong>FR</strong>-F720-110K ⎯ 600AF 500A 600AF 600A ⎯ S-N400*1 Selections for use of the Mitsubishi 4-pole standard motor with power supply voltage of 200VAC 50Hz.*2 Select the MCCB according to the power supply capacity.Install one MCCB per inverter.MCCB INV IMFor installations in the United States or Canada, use the appropriate UL and cUL listed Class RK5, Class Tor Class L type fuse or molded case circuit breaker (MCCB).(Refer to page 138.)MCCB INV IM*3 Magnetic contactor is selected based on the AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the magneticcontactor is used for emergency stop during motor driving, the electrical durability is 25 times.When using the MC for emergency stop during motor driving or using on the motor side during commercial-power supply operation, select theMC with class AC-3 rated current for the motor rated current.*4 When the breaker on the inverter primary side trips, check for the wiring fault (short circuit), damage to internal parts of the inverter, etc.Identify the cause of the trip, then remove the cause and power on the breaker.2INSTALLATION AND WIRING3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!