12.07.2015 Views

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WiringTypeTerminalSymbolTerminalNameDescriptionRatedSpecificationsRefer toOpen collectorPulseRUNSUOLIPFFUSEFMAMInverterrunningUp tofrequencyOverloadwarningInstantaneouspower failureFrequencydetectionOpen collectoroutput commonFor meterAnalog signaloutputSwitched low when the inverter output frequency is equal to or higherthan the starting frequency (initial value 0.5Hz). Switched high duringstop or DC injection brake operation.*Switched low when the output frequencyreaches within the range of ±10% (initialvalue) of the set frequency. Switched highduring acceleration/deceleration and at astop. *Switched low when stall prevention isactivated by the stall preventionfunction. Switched high when stallprevention is cancelled. *Switched low when an instantaneouspower failure and under voltageprotections are activated. *Switched low when the inverter outputfrequency is equal to or higher than thepreset detected frequency and highwhen less than the preset detectedfrequency. *Alarm code (4bit)outputPermissible load24VDC (27VDCmaximum) 0.1A(A voltage drop is3.4V maximumwhen the signal ison.)* Low indicatesthat the opencollector outputtransistor is on(conducts).High indicatesthat thetransistor is off(does notconduct).InstructionManual(applied)chapter 4InstructionManual(applied)chapter 4InstructionManual(applied)chapter 4InstructionManual(applied)chapter 4InstructionManual(applied)chapter 4Common terminal for terminals RUN, SU, OL, IPF, FU ----------------- ----Select one e.g. output frequency frommonitor items. (Not output during inverterreset.)The output signal is proportional to themagnitude of the correspondingmonitoring item.Output item:Output frequency(initial setting)Output item:Output frequency(initial setting)Permissible loadcurrent 2mA1440 pulses/s at60HzOutput signal 0 to10VDCPermissible loadcurrent 1mA(load impedance10kΩ or more)Resolution 8 bitInstructionManual(applied)chapter 4InstructionManual(applied)chapter 42(3) CommunicationTypeRS-485RS-485 terminalsTerminalSymbol—TXD+RXD+TXD-RXD-SGTerminalNamePUconnectorInvertertransmissionterminalInverterreceptionterminalEarth (Ground)DescriptionWith the PU connector, communication can be made through RS-485.(for connection on a 1:1 basis only). Conforming standard : EIA-485 (RS-485). Transmission format : Multidrop. Communication speed : 4800 to 38400bps. Overall length : 500mWith the RS-485 terminals, communication can be made through RS-485.Conforming standard : EIA-485 (RS-485)Transmission format : Multidrop linkCommunication speed : 300 to 38400bpsOverall length : 500mRefer to2526INSTALLATION AND WIRING21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!