4ADJUSTMENTSimple mode parameter list4 ADJUSTMENT4.1 Simple mode parameter listFor simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set thenecessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made fromthe operation panel (<strong>FR</strong>-DU07). For details of parameters, refer to Instruction Manual (applied) chapter 4.POINTOnly simple mode parameters are displayed by the initial setting of Pr. 160 User group read selection. Set Pr. 160 Usergroup read selection as required. (Refer to page 36 for parameter change.)Simple mode parameter listPr. 160Description9999Only the simple mode parameters can be displayed.(Initial Value)0 Simple mode and extended mode parameters can be displayed.1 Only the parameters registered in the user group can be displayed.ParameterNumberNameIncrements0 Torque boost 0.1%12MaximumfrequencyMinimumfrequency0.01HzInitialValue6/4/3/2/1.5/1%*1120/60Hz*2Range0 to 30%0 to 120Hz0.01Hz 0Hz 0 to 120Hz3 Base frequency 0.01Hz 60Hz 0 to 400Hz45Multi-speed setting(high speed)Multi-speed setting(middle speed)0.01Hz 60Hz 0 to 400Hz0.01Hz 30Hz 0 to 400HzApplicationsSet to increase a starting torque or when themotor with a load will not rotate, resulting in analarm [OL] and a trip [OC1]*1 Initial values differ according to the invertercapacity. (0.75K/1.5K to 3.7K/5.5K, 7.5K/11K to37K/45K, 55K/75K or more)Set when the maximum output frequency needto be limited.*2 Initial values differ according to the invertercapacity. (55K or less/75K or more)Set when the minimum output frequency needto be limited.Set when the rated motor frequency is 50Hz.Check the motor rating plate.Set when changing the preset speed in theparameter with a terminal.6Multi-speed setting(low speed)0.01Hz 10Hz 0 to 400Hz7 Acceleration time 0.1s 5/15s*3 0 to 3600s Acceleration/deceleration time can be set.8 Deceleration time 0.1s 10/30s*3 0 to 3600s*3 Initial values differ according to the invertercapacity. (7.5K or less/11K or more)96079125126160Electronic thermalO/L relayEnergy savingcontrol selectionOperation modeselectionTerminal 2frequency settinggain frequencyTerminal 4frequency settinggain frequencyUser group readselection0.01/0.1A*4Inverterratedcurrent0 to 500/0 to 3600A*41 0 0, 4, 91 0 0, 1, 2, 3, 4, 6, 70.01Hz 60Hz 0 to 400HzProtect the motor from overheat by the inverter.Set the rated motor current.*4 Setting increments and setting range differaccording to the inverter capacity.(55K or less/75K or more)The inverter output voltage is minimized whenusing for fan and pump applications.Select the start command location and frequencysetting location.Frequency for the maximum value of thepotentiometer (at 5V) can be changed.0.01Hz 60Hz 0 to 400Hz Frequency at 20mA input can be changed. 54Referto1 9999 0, 1, 9999 Make extended parameters valid —56573849583759615255

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!