4ADJUSTMENTSelection of the operation command andfrequency command locations (Pr. 79)4.6 Selection of the operation command and frequencycommand locations (Pr. 79)Select the start command location and frequency command location.ParameterNumberNameInitialValueSettingRangeDescriptionLED Indication: Off: OnUse external/PU switchover mode (pressto switchExternal operation mode0between the PU and external operation mode. (Refer topage 39))At power on, the inverter is in the external operationmode.PU operation mode1 Fixed to PU operation mode2Fixed to external operation modeOperation can be performed by switching between theexternal and NET operation mode.External operation modeNET operation modeExternal/PU combined operation mode 1Running frequencyStart signal79Operationmodeselection03PU (<strong>FR</strong>-DU07/<strong>FR</strong>-PU04/<strong>FR</strong>-PU07) setting orexternal signal input (multispeedsetting, acrossterminals 4-5 (valid whenAU signal turns on)).External signal input(terminal STF, STR)External/PU combined operation mode 2Running frequencyStart signal4External signal input(Terminal 2, 4, 1, JOG,multi-speed selection, etc.)Input from the PU (<strong>FR</strong>-DU07/<strong>FR</strong>-PU04/<strong>FR</strong>-PU07)( , )PU operation mode6Switchover modeSwitch among PU operation, external operation, andNET operation while keeping the same operation status.External operation modeNET operation modeExternal operation mode (PU operation interlock)X12 signal ON*PU operation modeOperation mode can be switched to the PU operationmode.7(output stop during external operation)External operation modeX12 signal OFF*Operation mode can not be switched to the PUoperation mode.* For the terminal used for the X12 signal (PU operation interlock signal) input, set "12" in Pr. 178 to Pr. 189 (input terminal function selection) to assignfunctions.For Pr. 178 to Pr. 189, refer to Instruction Manual (applied) chapter 4.When the X12 signal is not assigned, function of the MRS signal switches from MRS (output stop) to PU operation interlock signal.61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!