12.07.2015 Views

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

FR-F700 INSTRUCTION MANUAL (BASIC) - MRO Stop

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4ADJUSTMENTParameter listFunctionAnalog input selectionParameter73Relatedparameters242243Analog inputselectionTerminal 1 addedcompensationamount (terminal 2)Terminal 1 addedcompensationamount (terminal 4)1 10 to 7,10 to 170.1% 100% 0 to 100%0.1% 75% 0 to 100%252 Override bias 0.1% 50% 0 to 200%253 Override gain 0.1% 150% 0 to 200%267NameTerminal 4 inputselectionIncrementsInitialValue1 0012RangeYou can select the input specifications ofterminal 2 (0 to 5V, 0 to 10V, 0 to 20mA)and input specifications of terminal 1 (0 to±5V, 0 to ±10V).To change the terminal 2 to the voltageinput specification (0 to 5V/ 0 to 10V), turnOFF(initial status) the voltage/currentinput switch 2. To change it to the currentinput(0 to 20mA), turn ON the voltage/current input switch 2. Override andreversible operation can be selected.Set the ratio of added compensationamount when terminal 2 is the mainspeed.Set the ratio of added compensationamount when terminal 4 is the mainspeed.Set the bias side compensation value ofoverride function.Set the gain side compensation value ofoverride function.Terminal 4 input 4 to20mATerminal 4 input 0 to5VTerminal 4 input 0 to10VDescriptionTurn ON thevoltage/currentinput switch 1(initial status).Turn OFF thevoltage/currentinput switch 1.ParametercopyParameterclearAllparameterclear◦: enabled× : disabled◦ × ◦◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦◦ × ◦Parameter listNoise eliminationat the analog input74Input filter timeconstant1 1 0 to 8The primary delay filter time constant forthe analog input can be set.A larger setting results in a larger filter.◦ ◦ ◦Reset selection,disconnected PUdetection75Reset selection/disconnected PUdetection/PU stopselection1 140 to 3,14 to 17You can select the reset input acceptance,disconnected PU (<strong>FR</strong>-DU07/<strong>FR</strong>-PU04/<strong>FR</strong>-PU07) connector detection function and PUstop function.For the initial value, reset always enabled,without disconnected PU detection, andwith PU stop function are set.◦ × ×Output functionof alarm code76Fault code outputselection1 00 Without fault code output1 With fault code output2 Fault code output at fault occurrence only◦ ◦ ◦Prevention ofparameter rewrite77Parameter writeselection1 00 Write is enabled only during a stop1 Parameter write is disabled.2Parameter write is enabled in anyoperation mode regardless of operationstatus.◦ ◦ ◦Prevention ofreverse rotationof the motor78Reverse rotationprevention selection1 0Both forward and reverse rotations0allowed1 Reverse rotation disallowed2 Forward rotation disallowed◦ ◦ ◦75

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!