4ADJUSTMENTParameter listFunctionAcceleration/deceleration time settingMotor protectionfrom overheat(electronic thermalrelay function)DC injection brakeStarting frequencyParameter7 Acceleration time8 Deceleration time202144459 1011Relatedparameters51Acceleration/decelerationreference frequencyAcceleration/deceleration timeincrementsSecondacceleration/deceleration timeSeconddeceleration timeElectronic thermalO/L relaySecond electronicthermal O/L relay0.1/0.01s0.1/0.01s5/15s *410/30s*50 to 3600/360s0 to 3600/360s0.01Hz 60Hz 1 to 400Hz1 00.1/0.01s0.1/0.01s0.01/0.1A *60.01/0.1A *75s9999Inverterratedcurrent9999010 to 3600/360s0 to 3600/360sSet the motor acceleration time.*4 Initial values differ according to the invertercapacity. (7.5K or less/11K or more)Set the motor deceleration time.*5 Initial values differ according to the invertercapacity. (7.5K or less/11K or more)Set the frequency referenced asacceleration/deceleration time. Set thefrequency change time from stop to Pr. 20for acceleration/deceleration time.Increments: 0.1sRange: 0 to 3600sIncrements: 0.01sRange: 0 to 360sIncrements andsetting range ofacceleration/deceleration timesetting can bechanged.Set the acceleration/deceleration timewhen the RT signal is on.◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦Set the deceleration time when the RTsignal is on. ◦ ◦ ◦9999 Acceleration time = deceleration time0 to 500/0 to 3600A*60 to 500A0 to 3600A*799990 to 120HzDC injection brakeoperation frequency 0.01Hz 3Hz 9999DC injection brakeoperation time0.1s 0.5sSet the rated motor current.*6 The setting depends on the invertercapacity (55K or less/75k or more)Made valid when the RT signal is on.Set the rated motor current.*7 The setting depends on the invertercapacity (55K or less/75k or more)Second electronic thermal O/L relayinvalidSet the operation frequency of the DCinjection brake.Operate when the output frequencybecomes less than or equal toPr.13 Starting frequency.0 DC injection brake disabledSet the operation time of the DC injection0.1 to 10sbrake.0 DC injection brake disabled◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦◦ ◦ ◦12DC injection brake0.1% 4/2/1%Set the DC injection brake voltage (torque).*8 Initial values differ according to theoperation voltage*8 0.1 to 30%inverter capacity. (7.5K or less/11K to◦ ◦ ◦55K/75K or more)13 Starting frequency 0.01Hz 0.5Hz 0 to 60Hz Starting frequency can be set. ◦ ◦ ◦571NameHolding time at astartIncrementsInitialValue0.1s 9999Range0.0 to 10.0sDescriptionSet the holding time of Pr.13 Startingfrequency.9999 Holding function at a start is invalidParametercopyParameterclearAllparameterclear◦: enabled× : disabled◦ ◦ ◦Parameter listV/F pattern matchingapplications14Load patternselection1 10 For constant torque load1 For reduced-torque load◦ ◦ ◦69

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!