3DRIVE THE MOTORStart/stop from the operation panel (PUoperation mode)3.5.5 Perform frequency setting by analog (current input)POINT· Use / to give a start command.· Turn the AU signal on.· Pr. 79 Operation mode selection must be set to "4" (external/PU combined operation mode 2)[Connection diagram]InverterThree-phaseR/L1UAC power supply S/L2V MotorT/L3WAU signalAUOutput of theadjustment meter(4 to 20mADC)SD4(+)5(-) <strong>FR</strong>-DU07,OperationDisplay1. Screen at powering onThe monitor display appears.2. Press to choose the parameter setting mode.The parameter numberread previously appears.3. Pr. 79) appears.4. Press to read the currently set value." "(initial value) appears.5. Turn to change it to the settingvalue " ".6. Press to set.Flicker ··· Parameter setting complete!!7. Mode/monitor checkPress twice to choose the monitor/frequencymonitor.8. StartCheck that the terminal 4 input selection signal(AU) is on.Press the start switch (or ).FWD or REV of operation status indication flickers.CAUTIONWhen both the forward switch and reverseswitch turn on, the inverter will not start.Also, if both switch turn on while running,the inverter stops.( )Flickering45