2. Special Inspection, Continuous: Full-time observation of work requiringSpecial Inspection by an approved Special Inspector who is present inthe area where the Work is being performed.3. Special Inspection, Periodic: Part-time or intermittent observation ofwork requiring Special Inspection by an approved Special Inspectorwho is present in the area where the Work has been or is beingperformed, and at the completion of the Work.C. Structural Systems and Components:1. Diaphragm: Component of structural lateral load resisting systemconsisting of roof, floor, or other membrane or bracing system acting totransfer lateral forces to vertical resisting elements of structure.2. Drag Strut or Collector: Component of structural lateral load resistingsystem consisting of a diaphragm or shear wall element that collects andtransfers diaphragm shear forces to vertical force-resisting elements ordistributes forces within diaphragm or shear wall.3. Seismic-Force-Resisting System: That part of structural lateral loadresisting system that has been considered in the design to providerequired resistance to seismic forces identified on Drawings.4. Shear Wall: Component of structural lateral load resisting systemconsisting of a wall designed to resist lateral forces parallel to the planeof the wall. Unless noted otherwise on Drawings, load-bearing wallswith direct in-plane connections to roof and floors shall be considered tobe shear walls.5. Wind Force Resisting System: That part of the structural system that hasbeen considered in the design to provide required resistance to windforces identified on Drawings.D. Nonstructural Components:1. Architectural Component Supports: Structural members or assembliesof members which transmit loads and forces from architectural systemsor components to the structure, including braces, frames, struts, andattachments.2. Electrical Component Supports: Structural members or assemblieswhich transmit loads and forces from electrical equipment to thestructure, including braces, frames, legs, pedestals, and tethers, as wellas elements forged or cast as part of component for anchorage.3. Mechanical Component Supports: Structural members or assemblieswhich transmit loads and forces from mechanical equipment to thestructure, including braces, frames, skirts, legs, saddles, pedestals,snubbers, and tethers, as well as elements forged or cast as part ofcomponent for anchorage.SPECIAL INSPECTIONPW/WBG/382059AND TESTING AUGUST 15, 201201 45 33 - 2 ©COPYRIGHT 2012 CH2M HILL

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!