11.10 Rectangular Columns with Side Bars 377<br />

K ∙ ft<br />

Figure 11.11 Interaction diagram of the column section shown in Fig. 11.10.<br />

two cases in the table represent the pure moment (PM) or beam-action case for φ = 0.9 and φ =<br />

0.65 (M n = 391 K ⋅ ft). To be consistent with the design of beams due to bending moments, the ACI<br />

Code allows the use of φ = 0.9 with pure moment, so φM n = 352 K ⋅ ft instead of 254.2 K ⋅ ft. Also<br />

note that φ varies between 0.65 and 0.9 according to Eq. 11.2 for tied columns. Note that M n =<br />

391.1 K ⋅ ft.<br />

11.10 RECTANGULAR COLUMNS WITH SIDE BARS<br />

In some column sections, the steel reinforcement bars are distributed around the four sides of the<br />

column section. The side bars are those placed on the sides along the depth of the section in addition<br />

to the tension and compression steel, A s and A ′ s, and can be denoted by A ss (Fig. 11.12). In this case,<br />

the same procedure explained earlier can be applied, taking into consideration the strain variation<br />

along the depth of the section and the relative force in each side bar either in the compression or<br />

tension zone of the section. These are added to those of C c , C s ,andT to determine P n and Eq. 11.10<br />

becomes<br />

P n = C c + ΣC s − ΣT<br />

(11.10a)<br />

Example 11.7 explains this analysis. Note that if the side bars are located near the neutral axis<br />

(Fig. 11.12b), the strains—and, consequently, the forces—in these bars are very small and can be<br />

neglected. Those bars close to A s and A ′ s have appreciable force and increase the load capacity of<br />

the section.