24.02.2017 Views

Structural Concrete - Hassoun

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

928 Chapter 22 Prestressed <strong>Concrete</strong> Bridge Design<br />

WORKING STRESS DESIGN<br />

Allowable Stress (AASHTO Table 5.9.4.1.2-1, Table 5.9.4.2.1-1, and Table 5.9.4.2.2-1)<br />

1. Temporary tensile stress limit in prestressed concrete before losses, fully prestressed<br />

components<br />

In area with bonded reinforcement sufficient to resist √ the tensile force in the concrete computed<br />

assuming an uncracked section shall be 0.24 f ′ Cl (ksi).<br />

√<br />

√<br />

f ti_a = 0.24 f ci_BT ksi = 0.24 6 = 0.588 ksi<br />

2. Compressive stress limits in prestressed concrete at service limit state after losses, fully prestressed<br />

components<br />

f ci_a = 0.6f ′ = 3.6 ksi<br />

ci_BT<br />

f c1_a = 0.6f ′ = 0.6(8) =4.8<br />

c_BT<br />

f c_deck_a = 0.6f ′ = 0.6(4) =2.4 ksi<br />

c_deck<br />

f c2_a = 0.45f ′ = 0.45(8) =3.6 ksi<br />

c_BT<br />

f c3_a = 0.4f ′ = 0.4(8) =3.2 ksi<br />

c_BT<br />

Temporary compressive sress limit before<br />

losses, fully prestressed components<br />

Final compressive stress limit due to effective<br />

prestress, permanent loads, transient loads<br />

during shipping and handling<br />

Final compressive stress limit due to deck slab,<br />

effective prestress, permanent, transient<br />

loads during shipiing and handling<br />

Final compressive limit stress at service limit<br />

state after losses due to effective prestress<br />

and permanent loads<br />

Final compression − live load + one-half the<br />

sum of effective prestress and permanent<br />

loads<br />

3. Tensile stress limits in prestressed concrete at service limit state after lossess, fully prestressed<br />

components<br />

For components with bonded prestressing tendons that are subjected to not worse than moderate<br />

corrosion conditions shall be<br />

√<br />

f tf_a = 0.19<br />

√f ′ c_BT ksi = 0.19 8 = 0.537 ksi<br />

The minimum value of prestress force F f to ensure that the tension in the bottom fiber of the<br />

girder at midspan does not exceed the allowable stress of f tf (ksi) in the composite section<br />

under final service condition can be expressed as follows:<br />

where<br />

f bg = −F f<br />

A g<br />

− F f e m<br />

S bg<br />

+ M DC1 + M DC2<br />

S gb<br />

+ M DW + 0.8M LL<br />

S bc<br />

≤ f tf_a<br />

e m = 27.59 in.<br />

M DC1 = 2045.6 kip ⋅ ft<br />

Distance from center of gravity of girder to<br />

centroid of pretensioned strands<br />

Moment due to self-weight of girder