926 Chapter 22 Prestressed <strong>Concrete</strong> Bridge Design<br />

b. For two or more design lanes loaded:<br />

DV ext2 = e.DV int2 = 0.85(0.884) =0.751<br />

Distribution factors for shear at the exterior girder:<br />

DV ext = max(DV ext1 , DV ext2 )=1.2<br />

6. Skew correction factor for shear (AASHTO 4.6.2.2.3c)<br />

lane Therefore, use DF_VE = 1.2 lane<br />

θ = 0 Exterior and first interior beams on the obtuse side<br />

[ ] 0.3<br />

12Lt<br />

3 [ ]<br />

SC = 1.0 + 0.2 s<br />

12 × 100 × 8<br />

3<br />

tanθ = 1.0 + 0.2<br />

tan(0) =1<br />

K g 926,689<br />

Typically, maximum moments and shears are governed by live (truck) loads. In this case, interior<br />

girders will likely govern the design and a sample calculation will be performed for an<br />

interior girder design only.<br />

MOMENT DEMANDS<br />

The maximum moments due to dead loads and live loads occur at the midspan. Calculate the maximum<br />

moment due to dead loads.<br />

Unfactored Moment<br />

1. Dead Load<br />

x = 0.5L = 50 ft<br />

W DC1_NC = w g_int = 0.743 klf<br />

M DC1_NC = w DC1_NCx(L − x)<br />

2<br />

(0.743)(50)(100 − 50)<br />

=<br />

2<br />

= 928.4kip⋅ ft<br />

w DC1_C = w slab_int + w haunch_int<br />

= 0.85 + 0.044 = 0.894 klf<br />

M DC1_C = w DC1_Cx(l − x)<br />

2<br />

(0.894)(50)(100 − 50)<br />

=<br />

2<br />

= 1117.2 kip⋅ ft<br />

Distance at midspan from the left of the bridge<br />

Dead-load unit weight due to noncomposite<br />

section (DC1): girder only<br />

Maximum moment due to noncomposite<br />

section<br />

Dead-load unit weight due to composite<br />

section (DC1): deck slab and haunch<br />

Maximum moment acting on hardened girder:<br />

composite section<br />

The maximum moment due to DC1: girder, deck, and haunch<br />

M DC1 = M DC1_NC + M DC1_C = 928.4 + 1117.2 = 2045.6 kip⋅ ft<br />

The maximum moment due to DC2: railing and future utilities<br />

M DC2 = w DC2_intx(L − x) (0.205)(50)(100 − 50)<br />

= = 255.6 kip⋅ ft<br />

2<br />

2