24.02.2017 Views

Structural Concrete - Hassoun

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

934 Chapter 22 Prestressed <strong>Concrete</strong> Bridge Design<br />

a = β 1 c =(0.65)(3.322) =2.159 in.<br />

(<br />

M n = A ps f ps d p − 1 ) (<br />

2 a + A s f y d s − 1 )<br />

2 a − A ′ sf<br />

(d ′<br />

s ′ − 1 )<br />

2 a<br />

+ 0.85f ′ c_BT (b − b w )h f<br />

(<br />

=(5.625)(266.3)<br />

( 1<br />

2 a − 1 2 h f<br />

)<br />

67.47 − 2.159<br />

2<br />

φM n = φ f M n =(1.0)(8287) =8287 kip ⋅ ft<br />

s<br />

)<br />

+ 0 + 0 + 0 = 8287 kip ⋅ ft<br />

Check_flexure = if (φM n ≥ M u , “OK”, “NG”) =“OK”<br />

3. Check maximum and minimum reinforcement<br />

a. Maximum reinforcement (AASHTO 5.7.3.3.1): Provision deleted in 2005.<br />

b. Minimum reinforcement (AASHTO 5.7.3.3.2): At any section of a flexural component,<br />

the amount of prestressed and non-prestressd tensile reinforcement shall be adequate to<br />

devleop a factored flexural resistance, M r , at least equal to the lesser of:<br />

i. 1.2M cr :<br />

where<br />

f cpe = −F f<br />

A g<br />

− F f e m<br />

S bg<br />

= −942<br />

713 − 942(27.59)<br />

12,224<br />

=−3.488 ksi<br />

√<br />

f r = 0.37 (f ′ c_BT<br />

M dnc = M DC1 = 2045.6 kip ⋅ ft<br />

S c = S bc = 17407 in. 3<br />

S nc = S bg = 12224 in. 3<br />

( )<br />

Sc<br />

M cr = S c (f r + f cpe )−M dnc − 1 ≥ S<br />

S c f r<br />

nc<br />

Compressive stress in concrete due to effective<br />

prestress forces only at extreme fiber of section<br />

where tensile stress is caused by extremely applied<br />

loads<br />

ksi = 1.047 Modulus of rupure, AASHTO 5.4.2.6<br />

[[<br />

(<br />

( ) Sc<br />

M cr = max S c fr + f cpe − Mdnc<br />

Total unfactored dead-load moment acting on the<br />

noncomposite section<br />

Section modulus for the extreme fiber of the<br />

composite section where tensile stress is caused by<br />

extrernally applied loads<br />

Section modulus for the extreme fiber of the<br />

monolithic or noncomposite section where tensile<br />

stress is caused by externally applied loads<br />

)]<br />

− 1<br />

S nc<br />

, S c f r<br />

]<br />

[[<br />

= max (17,405) (1.047 − 3.498)−2045.6(12)<br />

1.2M cr = 1821.6 kip⋅ ft<br />

]<br />

(17,407) (1.047) = 1518 kip ⋅ ft<br />

( ) ]<br />

17,407<br />

− 1 ,<br />

12,224

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!