836 Chapter 20 Seismic Design of Reinforced <strong>Concrete</strong> Structures<br />

where<br />

s 0 = longitudinal spacing of transverse reinforcement within the length l 0<br />

h x = maximum horizontal spacing of hoop or crosstie legs on all faces of the column<br />

The remaining member length should be reinforced with the spiral or hoop transverse reinforcement<br />

spaced as follows: { }<br />

6 × smallest longitudinal diameter bar<br />

s ≤<br />

(20.48)<br />

6in.<br />

Transverse reinforcement should be designed to resist the design shear force. Design shear force<br />

for flexural members of special moment frames can be determined using the following equation:<br />

V u = M pr t<br />

+ M prb<br />

(20.49)<br />

l c<br />

where index t is for top and index b is for bottom of the column and l c is the length of the column.<br />

20.5.1.2.4 Summary: Design of the Special Moment-Resisting Frame Members Subjected<br />

to Bending and Axial Force<br />

Step 1.<br />

Step 2.<br />

Step 3.<br />

Step 4.<br />

Step 5.<br />

Determine seismic design category, base shear, lateral seismic force, and seismic shear<br />

according to 20.2 and 20.3.<br />

Calculate the member forces and using the different load combinations determine the<br />

values of member forces that govern the design. Design the reinforcement.<br />

Check whether the frame member is a flexural member or whether the member is subjected<br />

to the bending and axial force, and check general requirements for the special<br />

moment-frame member according to Section 20.5.1.2.1.<br />

Check the special requirements for the longitudinal reinforcement according to Section<br />

20.5.1.2.2.<br />

Design the transverse reinforcement for confinement and shear resistant using Section<br />

20.5.1.2.3.<br />

Example 20.7<br />

Design the edge column on the second floor of a building from Example 20.6.<br />

Given:<br />

First Floor:<br />

Second Floor:<br />

P u = 1022 K<br />

M nc = 580 kip ⋅ ft<br />

P u = 935 K<br />

M nc = 528 kip ⋅ ft<br />

M nb = 723 kip ⋅ ft