814 Chapter 20 Seismic Design of Reinforced <strong>Concrete</strong> Structures<br />

2. According to Table 20.7, for special moment-resisting frame, select R = 8.<br />

3. Equation 20.16 is not applicable since h x > 10 ft. The period of vibration of the structure is calculated<br />

according to Eq. 20.15 as follows:<br />

T a = C T h 3∕4<br />

n = 0.016 ×(6 × 12) 0.9 = 0.75 s<br />

4. Calculate seismic response coefficient as follows, and check for the limits:<br />

C s = S DS<br />

= 1.0<br />

R∕I e 8∕1.25 = 0.156<br />

C s,max =<br />

S DI<br />

(R∕I e )T = 0.4<br />

(8∕1.25)0.74 = 0.083<br />

Since S 1 = 0.6 g, Eq. should be used to calculate C s,min :<br />

C s,min = 0.5S 1 0.5 ×(0.6)<br />

= = 0.047<br />

(R∕I e ) 8∕1.25<br />

Since C s > C s,max , C s = 0.083.<br />

5. The total seismic weight is calculated as follows:<br />

W = w 1 + w 2 + w 3 + w 4 + w 5 + w 6 = 6 ×(1700) =10,200 K<br />

6. Calculate the seismic base using Eq. 20.10:<br />

V = C s W = 0.083 × 10200 = 846.6K≈ 847 K<br />

7. Calculation of F x , V x ,andM x (Fig. 20.6). Use Eq. 20.17 to calculate the seismic lateral force, F x ,<br />

as shown in the following table. The table also calculates the shear force for each floor level and<br />

the overturning moments as described in Eqs. 20.21 and 20.23.<br />

Floor<br />

Level<br />

Weight<br />

W i<br />

(K)<br />

Height<br />

h i<br />

(ft)<br />

W i<br />

h k*<br />

j Lateral<br />

(K ⋅ ft) C vx<br />

Force, F x<br />

(K)<br />

Shear<br />

Force, V x<br />

(K)<br />

Overturning<br />

Moment M x<br />

(K ⋅ ft)<br />

6 1,700 72 208,905 0.30 254 254 0<br />

5 1,700 60 170,165 0.24 207 461 3,052<br />

4 1,700 48 132,387 0.19 161 622 8,559<br />

3 1,700 36 95,783 0.14 117 739 16,061<br />

2 1,700 24 60,700 0.09 74 813 24,931<br />

1 1,700 12 27,831 0.04 34 847 34,689<br />

0 695,770 847 44,853<br />

*To calculate K, use Section 20.3.1. For T = 0.75 s, using linear interpolation k = 1.125.<br />

8. Calculation of drift: According to Table 20.7 for special moment-resisting frame C d = 5.5,<br />

I e = 1.25 (Table 20.1)<br />

h sx = 12 ft = 144 in.<br />

Floor Level δ xe<br />

(in.) δ x<br />

(in.) Δ (in.) P x<br />

(K) V x<br />

(K) θ<br />

6 1.26 5.54 1.23 1,700 254 0.013<br />

5 0.98 4.31 1.19 3,400 461 0.014<br />

4 0.71 3.12 1.10 5,100 622 0.014<br />

3 0.46 2.02 0.96 6,800 739 0.014<br />

2 0.24 1.06 0.80 8,500 813 0.013<br />

1 0.06 0.26 0.26 10,200 847 0.005