19.5 Design of Flexural Members 761<br />

If this condition is not met, then compression steel does not yield. In this case, A ′ s may be neglected<br />

(let A ′ s = 0), or alternatively, the stress in A ′ s may be determined by general analysis, as explained<br />

in Chapter 3.<br />

When prestressed and nonprestressed reinforcement are used in the same section, Eq. Eq.<br />

19.39 should read as follows:<br />

[<br />

f ps = f pu 1 − γ (<br />

p f pu<br />

ρ<br />

β p<br />

1 f c<br />

′ + d ( ))] ω − ω<br />

′<br />

(19.47)<br />

d p<br />

(ACI Code, Section 20.3.2.3.1). If any compression reinforcement is taken into account when calculating<br />

f ps ,theterm<br />

ρ p<br />

f pu<br />

f ′ c<br />

+ d d p<br />

(ω − ω ′ )<br />

must be greater than or equal to 0.17 and d ′ must be less than or equal to 0.15d p ,whered, d ′ ,andd p<br />

are the distances from the extreme compression fibers to the centroid of the nonprestressed tension<br />

steel, compression steel, and prestressed reinforcement, respectively,<br />

γ p = factorfortype of prestressing tendon<br />

⎧<br />

⎪ 0.55 for f py<br />

not less than0.8<br />

⎪ f pu<br />

⎪<br />

= ⎨0.40 for f py<br />

not less than0.85<br />

⎪<br />

f pu<br />

⎪<br />

⎪0.28 for f py<br />

not less than0.90<br />

⎩ f pu<br />

β 1 = 0.85 forf ′ c ≤ 4ksiless0.05 foreach1ksiincreaseinf ′ c, but β 1 ≥ 0.65.<br />

1. For rectangular sections, the ACI Code, Section 21.2.2.2, limits the reinforcement ratio as<br />

follows (ε t ≥ 0.005 for tension-controlled sections):<br />

where<br />

( ) fps<br />

ω p = ρ p<br />

ω = ρ<br />

f c<br />

′<br />

( fy<br />

f ′ c<br />

)<br />

ω p + d d p<br />

ω ≤ 0.32β 1<br />

and<br />

and<br />

ρ p = A ps<br />

bd<br />

ρ = A s<br />

bd<br />

(prestressed steel)<br />

(nonprestressed steel)<br />

2. If ordinary reinforcing bars A ′ s are used in the compression zone, then the condition becomes<br />

ω p + d d p<br />

(ω − ω ′ ) ≤ 0.32β 1<br />

where ω ′ = ρ ′ ( f y ∕f ′ c) and ρ ′ = A ′ s∕bd. This reinforcement limitation is necessary to ensure<br />

a plastic failure of underreinforced concrete beams.